SE98TK-T NXP Semiconductors, SE98TK-T Datasheet - Page 10

Board Mount Temperature Sensors I2C LOCAL +/- 2OC TS DIMM

SE98TK-T

Manufacturer Part Number
SE98TK-T
Description
Board Mount Temperature Sensors I2C LOCAL +/- 2OC TS DIMM
Manufacturer
NXP Semiconductors
Datasheet

Specifications of SE98TK-T

Temperature Threshold
+ 6 C
Full Temp Accuracy
+/- 4 C
Package / Case
SOT-908
Digital Output - Bus Interface
2-Wire, I2C
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 20 C
Output Type
Digital
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
SE98TK,118
NXP Semiconductors
SE98_4
Product data sheet
7.4 Conversion rate
7.5 Power-up default condition
7.6 Device initialization
The conversion time is the amount of time required for the ADC to complete a temperature
measurement for the local temperature sensor. The conversion rate is the inverse of the
conversion period which describes the number of cycles the temperature measurement
completes in one second—the faster the conversion rate, the faster the temperature
reading is updated. The SE98’s conversion rate is at least 8 Hz or 125 ms.
After power-on, the SE98 is initialized to the following default condition:
SE98 temperature sensors have programmable registers, which, upon power-up, default
to zero. The open-drain EVENT output is default to being disabled, comparator mode and
active LOW. The alarm trigger registers default to being unprotected. The configuration
registers, upper and lower alarm boundary registers and critical temperature window are
defaulted to zero and need to be programmed to the desired values. SMBus TIMEOUT
feature defaults to being enabled and can be programmed to disable. These registers are
required to be initialized before the device can properly function. Except for the SPD,
which does not have any programmable registers, and does not need to be initialized.
Table 4
registers.
– Competitor devices: If the EVENT output is not cleared before or when the
– Work-around: Always clear the EVENT output before temperature exceeds the
– SE98B will keep EVENT asserted after the temperature drops below the critical
Starts monitoring local sensor
EVENT register is cleared—EVENT output is pulled HIGH by external pull-ups
EVENT hysteresis is defaulted to 0 C
Command pointer is defaulted to ‘00h’
Critical Temp, Alarm Temperature Upper and Lower Boundary Trip register are
defaulted to 0 C
Capability register is defaulted to ‘0015h’
Operational mode: comparator
SMBus register is defaulted to ‘00h’
temperature is in the critical temperature threshold, EVENT will remain asserted
after the temperature drops below the critical temperature until a Clear EVENT
command.
critical temperature.
temperature until a Clear EVENT command de-asserts EVENT.
shows the default values and the example value to be programmed to these
Rev. 04 — 2 February 2009