ES-UA-5A BANNER ENGINEERING, ES-UA-5A Datasheet - Page 7

no-image

ES-UA-5A

Manufacturer Part Number
ES-UA-5A
Description
Sensor, E-stop Module, output 6A,
Manufacturer
BANNER ENGINEERING
Type
Safetyr
Datasheets

Specifications of ES-UA-5A

Contact Form
4-NO/1-NC
Dimensions
45mmW×84mmH×118mmD
Enclosure Rating
IP20
Ip Rating
IP20
Mounting Type
DIN Rail
Number Of Outputs
8
Output Type
Relay
Power, Rating
4 W
Primary Type
Controller
Standards
UL, CSA, CE
Voltage, Supply
115/12 to 24 VAC/VDC
Coil Voltage Vdc Nom
24V
Coil Resistance
250ohm
Contact Current Max
6A
Contact Voltage Ac Nom
24V
Contact Voltage Dc Nom
250V
Contact Configuration
SPST-NC
No. Of Poles
1
Relay Mounting
DIN Rail
Lead Free Status / Rohs Status
RoHS Exempt Product
For Use With
Emergency Stop
ES-UA-5A and ES-VA-5A E-Stop Safety Modules
NOTE: The minimum amount of time for the Module to detect a STOP condition is 15 ms. This "recovery time" (OFF-
state) is required for the internal integrity tests to complete, allowing a reliable reset to occur. A lockout may occur
if the Module is cycled too quickly. To clear the lockout, the inputs must be re-cycled, meeting the minimum recovery
time requirements.
Connection of Safety Switches
Connection of Reset Switch
The reset circuit switch can be any mechanical switch, such as a normally open momentary switch, or a two-position
key switch. The reset switch must be capable of reliably switching 12 to 30V dc at 20 to 50 milliamps. As shown in
the hookup drawings, the reset switch connects between Safety Module terminals S33 and S34.
The reset switch must be located outside of
and must be positioned so that any area of dangerous motion may be observed by the switch operator
during the reset procedure. See warning below.
P/N 122365 rev. C
When two or more safety devices are used, each device must be individually actuated, causing a STOP or
open-contact condition, then reset/rearmed and the Safety Module reset (if using manual reset mode). This
allows the monitoring circuits to check each device and its wiring to detect faults. Failure to test each device in-
dividually in this manner could result in undetected faults and create an unsafe condition which could result
in serious injury or death.
The Safety Module may be used to monitor safety interlocking
switches that determine the position of a guard or gate. To
achieve Category 4 operation per ISO 13849-1 (EN 954-1), two
positive-opening safety switches must operate concurrently when
the guard or gate is opened (see figure at right).
The Safety Module verifies concurrent opening of two contacts
– one from each safety switch. Reset of the Safety Module is not
possible if one switch fails to open, or if a short circuit between
the safety interlocking switches occurs.
The reset switch must be accessible only from outside, and in full view of, the hazardous area. Reset
switches must also be out of reach from within the safeguarded space, and must be protected against
unauthorized or inadvertent operation (e.g., through the use of rings or guards). If any areas are not visible from
the reset switch(es), additional means of safeguarding must be provided. Failure to do so could result in serious
bodily injury or death.
WARNING . . . Multiple Safety Devices
WARNING . . . Reset Switch Location
Banner Engineering Corp. - Minneapolis, MN USA - www.bannerengineering.com
and not be accessible from
Tel: 763.544.3164
Figure 3: Hookup using contacts from two
safety switches
Safety Gate or Guard with end-of-travel stops and two
individually mounted Safety Interlocking Switches
the area of dangerous motion,
OPEN
S11 S21
S22
S12
7

Related parts for ES-UA-5A