MSO-0008P-012 NCC, MSO-0008P-012 Datasheet - Page 92

no-image

MSO-0008P-012

Manufacturer Part Number
MSO-0008P-012
Description
Socket, Relay; 8 Pin Octal
Manufacturer
NCC
Type
Octalr
Datasheet

Specifications of MSO-0008P-012

Number Of Contacts
8
Time Range
0.05 Sec. to 999 Min.
Output Rating
10 A @ 240 VAC Max.; 100 mA @ 5 VDC Min.
Operating Temperature
–23°C to +55°C
4-20
AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com
Intelligent Dust Collector Controller
Remote Input/Output Module
Model DNC-T2300-I/O
FEATURES
The Model DNC-T2300-I/O module provides
several functions. It communicates with a
T2310 or T2320 Dust Collector Timer via the
RS232 port to form an Enhanced Timer sys-
tem, and it communicates pertinent system
data to remote control/display devices via
the 2 wire Enhanced Timer Network. It also
incorporates three 4-20 mA current loop
inputs, three contact closure type inputs,
and one type J thermocouple input. In addi-
tion, the I/O board provides 16K bytes of
ORDERING INFORMATION
Enclosure
ACCESSORY
Enhances T2310 and T2320 timer oper-
ation
Monitors three 4-20 mA analog inputs
Monitors three switched inputs
Monitors one type J thermocouple
Operating temperature range from
-40°C to 65°C
Communicates via RS232 port to intel-
ligent controller
Communicates via 2 wire network to
remote sites
Interconnectable for overall system
management
Large storage capacity for historical
trending of system data
Aids in system diagnostics
Increases overall system efficiency
Conformally coated for protection
against vibration, humidity, and con-
tamination
Metal chassis provided: for mounting
directly into NEMA 4 box
Timer functionally tested to eliminate
field failures
One Year Warranty: warranted to be
free from defects in materials or work-
manship for one year from date of
manufacture
INPUT VOLTAGE
105 to 135 VAC
210 to 270 VAC
DUST COLLECTOR CONTROLS
File #E65038
DIMENSIONS
10” x 8” x 4”
DNC-T2310-A220
DNC-T2310-A10
PART NUMBER
BOX-A1008-CHNF
PART NUMBER
non-volatile memory for the storage of
up to one year of input trending data. The
I/O board requires either a T2310 or T2320
Timer to program and operate the board
and a T2300 Display Panel to access data
trending reports.
ity to the Intelligent Dust Collector Controller
system. It can monitor, display, alert, and
store dust collector system parameters from
pressure sensors, emission monitors, ple-
num air flow sensors, broken bag detectors,
fan motor current sensors and any other
device which has a 4-20 mA current output
or contact closure output. The unit works
in conjunction with the T2310 and T2320
Timers and also with the DNC-T2300-DSP
Display Panel.
Operating Logic: Upon application of
power to the unit, communication will be
established with the T2310 or T2320 Timer
via the RS232 port. The I/O board can then
be configured for the inputs provided to it
by using the keypad on the controller. Alarm
setpoints and 4-20 mA scaling can be pro-
grammed for different types of inputs to be
displayed in a meaningful fashion on the
The I/O board offers significant versatil-
L1 L2
L1
National Controls
Corporation
L2
DIFFERENTIAL PRESSURE ( P)
INTELLIGENT DUST CONTROL
1725 Western Dr.
West Chicago, IL. 60185
SOL
COM
MODEL NO.: DNC-T2310-010
INPUT VOLTAGE:120 VAC, 10VA
S/N:
INCHES OF WATER
1
National Controls
Corporation
Date Code:
2
Model DNC-T2310-010
RS-232 Null Modem Cable
3
DNC-T2310-010
D
4
LOW SIDE
PRESSURE
CONNECTIONS:
HI SIDE
OUTPUTS
5
ITEM
6
CONNECTOR
VALUE
RS232
7
8
OUTPUT
ALARM
CANCEL
STEP
OUTPUT
ALARM
T2310 & I/O Board Wiring Diagram
BYPASS
INPUT
ALARM
INPUT
9
10
controller’s 8 character display and
output via the two wire Enhanced
Timer Network to the DNC-T2300-
DSP remote display panel.
Inputs: There are three gener-
al purpose 4-20mA current loop
inputs which are configured by the
Timer. Depending on how the par-
ticular 4-20 mA inputs are config-
ured, the messages that appear
on the Timer’s display would either
show a generic range of 0-100%
based on the 4-20 mA input or
data units specific to three pre-pro-
grammed sensing devices would
be displayed.
switched inputs which will moni-
tor and report up to two contact
closures as alarm conditions to
the Timer, and one contact clo-
sure input which allows the user to
place the Enhanced Timer system
in standby mode.
There are two general purpose
DNC-T2300-I/O
Network Connection
to DSP-T2300-010

Related parts for MSO-0008P-012