H3AM-NS-A AC100-240 Omron Automation, H3AM-NS-A AC100-240 Datasheet - Page 5

no-image

H3AM-NS-A AC100-240

Manufacturer Part Number
H3AM-NS-A AC100-240
Description
Relay; E-Mech; Timing; On Delay; DPDT; Cur-Rtg 5A; Ctrl-V 100-240AC; Vol-Rtg 250AC
Manufacturer
Omron Automation
Datasheet

Specifications of H3AM-NS-A AC100-240

Contact Form
DPDT
Current, Rating
5 A
Function
Timing
Mounting Type
Panel
Relay Type
Electro Mechanical
Standards
UL, CSA, CE
Temperature, Operating, Maximum
55 °C
Temperature, Operating, Minimum
-10 °C
Timer Type
On Delay
Timing Range
0.5 sec. to 30 hrs.
Voltage, Control
240 VAC
Voltage, Rating
250 VAC
Lead Free Status / Rohs Status
RoHS Compliant part
Dimensions
Note: All units are in millimeters unless otherwise indicated.
H3AM (Flush Mounting)
■ Accessories (Order Separately)
Waterproof Packing
(Provided with H3AM-NS@-@-300 models.)
Installation
■ Internal Connections and Terminal Arrangement
Note: The R2 relay can be switched between instantaneous and time-limit contacts and thus the contact symbol is shown as follows:
Y92S-35
Power Supply
H3AM-NS
1
2
3
4
5
96
R1
(See note)
R2
96
Note: Use Waterproof Packing to provide a level of water protection
that complies with IP65 standards.
Depending on the operating environment, the Waterproof
Packing may deteriorate, contract, or harden and so regular
replacement is recommended.
10
6
7
8
9
27.5 dia.
33
17.7 17.5
77.5 dia.
85
Power
Supply
Note: Tightening torque for panel mounting is as follows:
20.1
H3AM-NSR
300 m N·m ±50 m N·m
46 70
Use the same power source for the power supply and
reset input and wire the circuit so that the terminals (1)
and (10) terminals (2) and (9) become the same phase
respectively.
1
2
3
4
5
Four, M4x17.5 screw boss
70
R1
R2
Mounting Holes
70 ±
10
6
7
8
9
81-dia. hole
0.4
Reset
Four, 5-dia. holes
H3AM
70 ±
0.4
6