DSO6104A Agilent Technologies Test Equipment, DSO6104A Datasheet - Page 7

no-image

DSO6104A

Manufacturer Part Number
DSO6104A
Description
Oscilloscope; 6.3 in. Diagonal TFT LCD; 4; + 2%; + 5 V; 50 Ohms
Manufacturer
Agilent Technologies Test Equipment
Type
Digitalr
Datasheet

Specifications of DSO6104A

Accuracy
± 2%
Bandwidth
1000 MHz
Brand/series
DSO6000A Series
Configuration
Bench/Portable
Display Type
Color TFT LCD
Impedance, Input
50 Ohms
Memory
8 Mpts
Number Of Channels
4
Resolution
XGA-768 Vertical by 1024 Horizontal Points(Screen Area), 640 Vertical by 1000 Horizontal Points(Waveform Area), 256 Levels of Intensity Scale
Sample Rate
4 GS/s
Voltage, Input
± 5 V
Performance characteristics
Horizontal
Range
Resolution
Time scale accuracy*
Vernier
Delay range
Analog delta-t accuracy
Logic delta-t accuracy
Modes
XY
Reference positions
Segmented memory rearm time
Trigger system
Sources
Modes
Holdoff time
Trigger jitter
*
Denotes warranted specifications for units manufactured after January 1, 2008. Specifications are valid after a 30 minute warm-up period and within 10 °C of firmware
calibration procedure.
MSO/DSO601xA: 5 nsec/div to 50 sec/div
MSO/DSO603xA: 2 nsec/div to 50 sec/div
MSO/DSO605xA: 1 nsec/div to 50 sec/div
MSO/DSO610xA: 500 psec/div to 50 sec/div
2.5 psec
≤ ± (15 + 2*(instrument age in years)) ppm
1-2-5 increments when off, ~25 minor increments between major settings when on
Pre-trigger (negative delay): Greater of 1 screen width or 1 ms (with 8 Mpts memory option)
Post-trigger (positive delay): 1 s to 500 seconds
Same channel: ±0.0015% reading ±0.1% screen width ±20 ps
Channel-to-channel: ±0.0015% reading ±0.1% screen width ±40 ps
Same channel example (MSO/DSO605xA):
For signal with pulse width of 10 µs, scope set to 5 µs/div (50 µs screen width),
delta-t accuracy = ±{0.0015% (10 µs) + 0.1% (50 µs) + 20 ps} = 50.17 ns
Same channel: ±0.005% reading ±0.1% screen width ±(1 logic sample period, 1 ns)
Channel-to-channel:
±0.005% reading ±0.1% screen width ±(1 logic sample period) ±chan-to-chan skew
Same channel example:
For signal with pulse width of 10 µs, scope set to 5 µs/div (50 µs screen width),
delta-t accuracy = ±{0.005% (10 µs) + 0.1% (50 µs) + 1 ns} = 51.5 ns
Main, delayed, roll, XY
Bandwidth: Max bandwidth
Phase error @ 1 MHz: <0.5 degrees
Z Blanking: 1.4 V blanks trace (use external trigger on MSO/DSO6xx2A,
channel 4 on MSO/DSO6xx4A)
Left, center, right
8 µs (minimum time between trigger events)
MSO6xx2A: Ch 1, 2, line, ext, D15 - D0
DSO6xx2A: Ch 1, 2, line, ext
MSO6xx4A: Ch 1, 2, 3, 4, line, ext, D15 - D0
DSO6xx4A: Ch 1, 2, 3, 4, line, ext
Auto, Normal (triggered), single
~60 ns to 10 seconds
15 ps rms
(continued)