IDT82V2041EPP IDT, Integrated Device Technology Inc, IDT82V2041EPP Datasheet - Page 51

no-image

IDT82V2041EPP

Manufacturer Part Number
IDT82V2041EPP
Description
IC LIU T1/J1/E1 1CH 44-TQFP
Manufacturer
IDT, Integrated Device Technology Inc
Type
Line Interface Units (LIUs)r
Datasheet

Specifications of IDT82V2041EPP

Protocol
E1
Voltage - Supply
3.13 V ~ 3.47 V
Mounting Type
Surface Mount
Package / Case
44-TQFP, 44-VQFP
Number Of Transceivers
1
Screening Level
Industrial
Mounting
Surface Mount
Package Type
TQFP
Operating Temperature (min)
-40C
Operating Temperature (max)
85C
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Number Of Drivers/receivers
-
Lead Free Status / RoHS Status
Not Compliant, Contains lead / RoHS non-compliant
Other names
82V2041EPP

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
IDT82V2041EPP
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Part Number:
IDT82V2041EPP8
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Part Number:
IDT82V2041EPPG
Manufacturer:
IDT
Quantity:
351
Part Number:
IDT82V2041EPPG
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Part Number:
IDT82V2041EPPG8
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Table-43 STAT0: Line Status Register 0 (real time status monitor) (Continued)
Table-44 STAT1: Line Status Register 1 (real time status monitor)
Programming Information
IDT82V2041E
Symbol
Symbol
LOS_S
RLP_S
AIS_S
DF_S
-
-
(R, Address = 17H)
(R, Address = 18H)
7-6
4-0
Bit
Bit
2
1
0
5
Default
Default
00000
00
0
0
0
0
Line driver status indication
= 0: Normal operation
= 1: Line driver short circuit is detected.
Note:
If DF_IM=0
A ‘0’ to ‘1’ transition on this bit causes an interrupt if DF _IES bit is ‘0’.
Any changes of this bit causes an interrupt if DF_IES bit is set to ‘1’.
Alarm Indication Signal status detection
= 0: No AIS signal is detected in the receive path
= 1: AIS signal is detected in the receive path
Note:
If AIS_IM=0
A ‘0’ to ‘1’ transition on this bit causes an interrupt if AIS _IES bit is ‘0’.
Any changes of this bit causes an interrupt if AIS_IES bit is set to ‘1’.
Loss Of Signal status detection
= 0: Loss of signal on RTIP/RRING is not detected.
= 1: Loss of signal on RTIP/RRING is detected.
Note:
If LOS_IM=0
A ‘0’ to ‘1’ transition on this bit causes an interrupt if LOS _IES bit is ‘0’.
Any changes of this bit causes an interrupt if LOS_IES bit is set to ‘1’.
Reserved.
Indicating the status of Remote Loopback
= 0: The remote loopback is inactive.
= 1: The remote loopback is active (closed).
Reserved
SINGLE CHANNEL T1/E1/J1 SHORT HAUL LINE INTERFACE UNIT
51
Description
Description
December 9, 2005

Related parts for IDT82V2041EPP