S3K2U2200-5 SOLA HEVI DUTY, S3K2U2200-5 Datasheet - Page 7

UPS - Uninterruptible Power Supplies 2200VA/1650W 230V

S3K2U2200-5

Manufacturer Part Number
S3K2U2200-5
Description
UPS - Uninterruptible Power Supplies 2200VA/1650W 230V
Manufacturer
SOLA HEVI DUTY
Datasheet

Specifications of S3K2U2200-5

Power Rating
2200 VA
Output Voltage Rating
230 V
Number Of Outlets
9
Interface Port
USB / SNMP
Runtime (full Load)
5 min
Runtime (half Load)
12 min
Topology
Line Interactive
Tower / Rackmount
Tower / Rackmount
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
I
MPORTANT
SAVE THESE INSTRUCTIONS
This manual contains important safety instructions that should be followed during the installation
and maintenance of the UPS and batteries. Please read this manual thoroughly before attempting to
install or operate this UPS.
CONDITIONS OF USE: The mains supply socket must be within 2m (6.5 ft.) of the UPS and be eas-
ily accessible.
!
!
!
!
S
WARNING
SAFETY PRECAUTIONS
To prevent the risk of fire or electric shock, install the UPS in a temperature and humidity
controlled room, free of conductive contaminants, moisture, flammable liquids, gases and
corrosive substances.
Operate the UPS only from a properly grounded (earthed) 220-240 VAC, 50Hz or 60Hz AC
supply.
To reduce the risk of electric shock, do not remove the cover—it has no user-serviceable parts
inside except the internal battery pack. Some components are live, even when AC power is
disconnected. For internal battery pack servicing, follow the instructions provided in 10.3 -
Battery Replacement. For other service, contact a qualified technician.
WARNING
ELECTRICAL PRECAUTIONS
• This UPS should not be supplied from electrical power systems of the IT (Impedance á
• The UPS must be earthed/grounded at all times during operation. Connect only to a mains
CAUTION
Although your UPS has been designed and manufactured to ensure personal safety, improper
use can result in electrical shock or fire. To ensure safety, please observe the following rules:
• Turn Off and unplug your UPS before cleaning. Do not use liquid or aerosol cleaners. A dry
• Do not install or operate your UPS in or near water.
• Do not place UPS on an unstable cart, stand or table.
• Do not place UPS under direct sunlight or close to heat emitting sources.
• Never block or insert any objects into the ventilation holes or other openings of the UPS.
• Do not place UPS power cord in any area where it may get damaged by heavy objects.
WARNING
If your UPS demonstrates any of the following conditions, turn Off and unplug your UPS from
the outlet and contact your local distributor, Sola/Hevi-Duty representative or Sola/Hevi-Duty
Technical Services:
• The power cord or plug is damaged.
• Liquid has been spilled on the UPS.
• The circuit protector trips frequently.
• The UPS does not operate in accordance with the user manual.
AFETY
Terre) type (IEC 364 - Electrical Installation of Buildings).
supply socket outlet with an earth/ground connection.
cloth is recommended to remove dust from the surface of your UPS.
Keep all vents free of dust accumulation that could restrict air flow.
I
NSTRUCTIONS
1