4.3.3
Figure 30
•
Figure 30
When initiating an activation from the terminal side, the LT must be in the
DEACTIVATED state. For a TE initiated activation to be successful the downstream LT
C/I-code must be DC. This is not the case if the DEACTIVATED state has been entered
from the RESET or TEST state (the last code is DR in this case).
•
Data Sheet
INFO 0
INFO 0
INFO 1
S/T
depicts the procedure if the activation has been initiated by the terminal side.
Complete Activation Initiated by TE
Complete Activation Initiated by TE
IOM - 2
TIM
PU
DC
AR
DI
DC
AR
R
SL2 act = 0 de a = 1 uoa = 0
U - Reference Point
77
SL3T uoa = 1
SN3 sai = 1
SN0
SN1
SN0
SN2
SL0
SL1
TN
Operational Description
IOM - 2
ARM
UAI
AR
R
DC
DI
actby NT_2b1q.em f
PEF 24911
2001-07-16
Related parts for PEB24911HV13
Image
Part Number
Description
Manufacturer
Datasheet
Request
R
![PEB22811H-V13X](/images/manufacturer_photos/0/3/379/lantiq_tmb.jpg)
Part Number:
Description:
Manufacturer:
Lantiq
Datasheet:
![ADM6996L-AA-T-1](/images/manufacturer_photos/0/3/379/lantiq_tmb.jpg)
Part Number:
Description:
Manufacturer:
Lantiq
Datasheet:
![PEF22810T-V21TR](/images/manufacturer_photos/0/3/379/lantiq_tmb.jpg)
Part Number:
Description:
Manufacturer:
Lantiq
Datasheet: