LI55-1411 Flowline, LI55-1411 Datasheet

no-image

LI55-1411

Manufacturer Part Number
LI55-1411
Description
Panel Meter, 6 Digit LED, w/ 4 Relays and 4-20 mA Repeater, DataView Series
Manufacturer
Flowline
Type
Digitalr
Datasheet

Specifications of LI55-1411

Brand/series
DataView
Display Digit Height
0.6 and 0.46 In.
Display Type
LED
Enclosure Rating
NEMA 4X
Input Type
4-20 mA or 0 to 10 VDC
Mounting Type
Panel
Number Of Digits
6
Number Of Inputs
1
Primary Type
Panel Meter
Signal, Input
4-20 mA or 0 to 10 VDC
Special Features
2-Line Display
Termination
Terminals
Voltage, Supply
85 to 265 VAC
DataView
APPLICATION
The general purpose meter displays
engineering units with one 4-20 mA or
0-10 VDC transmitter input channel and
is offered in three configurations with
optional 2 or 4 relays, 4 or 8 set points
and an isolated 4-20 mA repeater. Each
relay can be configured on a single set
point or latched on two set points for
automatic fill or empty control including
duplexing. For field mount installations,
order the single or two meter NEMA
box.
(92 mm)
Configuration (1)
Repeater output
3.61"
DataView
(62 mm)
0
2
4
1
2.45"
0
Meter only
Meter with 2 relays
Meter with 4 relays
No repeater
4-20 mA repeater
(15 mm)
0.59"
(45 mm)
1.76"
We Do Your Level Best
(119 mm)
(81 mm)
4.68"
3.2"
(91 mm)
3.6"
(64 mm)
2.5"
(92 mm)
L I 5 5-1
3.61"
(62 mm)
2.45"
FEATURES
Universal Panel Meter
LI55 Series
(15 mm)
0.59"
Bright 6-digit LED main display and
secondary unit display with relay sta-
tus indicators
1/8 DIN enclosure with NEMA 4X
faceplate and shallow depth case
32-point linearization function for
volumetric tank measurement
Non-volatile memory with security
password protected lock out
Isolated 4-20 mA repeater output with
40 mA internal power supply
(45 mm)
1.76"
Advanced Meter & Controller
(119 mm)
(81 mm)
4.68"
3.2"
(91 mm)
3.6"
1
(64 mm)
2.5"
Ordering Notes
1) For field mount installation in a NEMA 4X
polycarbonate windowed enclosure, order the
LM92-1001 (single meter box) or the LM93-
1001 (two meter box).
TECH TIP
For field mount installation in a rugged
NEMA 4X, corrosion resistant PC win-
dowed enclosure, order the LM92 single
meter or the LM93 two meter box. Each
comes with precut panels and mounting
SPECIFICATIONS
hardware. It's indication and
control made simple.
65
Panel Meter
LI55
IP
Display type:
Display units:
Decimal point:
Display output:
Display height:
LED indication:
User interface:
Linearization:
Memory:
Sensor input:
Supply voltage:
Consumption:
Sensor supply:
Repeater ouput:
Contact type:
Contact rating:
Ambient temp.:
Enclosure type:
Enclosure rating:
Enclosure mat’l:
Compliance:
Classification:
Approvals:
LED, 6-digit
Engineering
Floating
-99999 to 999999
Main: 0.6” (15 mm) high
Second: 0.46” (12 mm) high
Relay status
Four push button
2-32 point function
Non-volatile
(1) 4-20 mA or 0-10 VDC
transmitter
85-265 VAC
@ 50-60 Hz.
20 watts max.
24 VDC +/- 5% @ 200 mA
4-20 mA, 24 VDC +/- 5%
@ 40 mA
12_1: (2) SPDT (Form C)
14_1: (4) SPDT (Form C)
3A @ 30 VDC or 250
VAC resistive load
F: -40˚ to 149˚
C: -40˚ to 65˚
1/8 DIN panel meter
NEMA 4X (IP65) faceplate
Polycarbonate
CE: EN61010-1:2001
General purpose
cULus, UL508
LM92-1001
Shown
DS301033 REV A
© 2008 Flowline Inc.