TLE6225GXT Infineon Technologies, TLE6225GXT Datasheet - Page 6

no-image

TLE6225GXT

Manufacturer Part Number
TLE6225GXT
Description
Manufacturer
Infineon Technologies
Datasheet

Specifications of TLE6225GXT

Lead Free Status / Rohs Status
Not Compliant
Diagnostic Table
Operating Condition
Standby
Normal function
Overtemperature
Open load or short to ground
X = not relevant
*selective thermal shutdown for each channel at overtemperature
Fault Distinction
Open load/short to ground is recognised in OFF-state. Overtemperature as a result of an
overload or short to battery can only arise in ON-state. If there is only one fault at a time, it is
possible to distinguish which channel is affected with which fault.
V2.1
Enable
Input
ENA
H
H
H
H
H
H
H
H
H
H
L
Page
Program
Input
PRG
X
H
H
H
H
H
L
L
L
L
L
6
Control
Input
IN
X
H
H
H
H
H
L
L
L
L
L
Data Sheet TLE 6225 G
Output
Power
OFF *
OFF *
OUT
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
Diagnostic
26.Aug. 2002
FAULT
Output
H
H
H
H
H
H
L
L
L
L
L