M28W640FSU70ZA6 Micron Technology Inc, M28W640FSU70ZA6 Datasheet - Page 21

no-image

M28W640FSU70ZA6

Manufacturer Part Number
M28W640FSU70ZA6
Description
Manufacturer
Micron Technology Inc
Datasheet

Specifications of M28W640FSU70ZA6

Cell Type
NOR
Density
64Mb
Access Time (max)
70ns
Interface Type
Parallel
Address Bus
22b
Operating Supply Voltage (typ)
3/3.3V
Operating Temp Range
-40C to 85C
Package Type
TBGA
Sync/async
Asynchronous
Operating Temperature Classification
Industrial
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (max)
3.6V
Word Size
16b
Number Of Words
4M
Supply Current
18mA
Mounting
Surface Mount
Pin Count
64
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M28W640FSU70ZA6
Manufacturer:
ST
Quantity:
20 000
Part Number:
M28W640FSU70ZA6 K
Manufacturer:
ST
0
Part Number:
M28W640FSU70ZA6E
Manufacturer:
ST
Quantity:
12
M28WxxxFS, M28WxxxFSU
6.5
6.6
Block Erase command
The Block Erase command can be used to erase a block. It sets all the bits within the
selected block to ’1’. All previous data in the block is lost. If the block is protected then the
Erase operation will abort, the data in the block will not be changed and the Status Register
will output the error.
Two Bus Write cycles are required to issue the command:
If the second bus cycle is not Write Erase Confirm (D0h), Status Register bits b4 and b5 are
set and the command aborts.
Erase aborts if Reset turns to V
operation is aborted, the block must be erased again.
During Erase operations the memory will accept the Read Status Register command and
the Program/Erase Suspend command, all other commands will be ignored. Typical Erase
times are given in
See
using the Erase command.
Program command
The memory array can be programmed word-by-word. Two bus write cycles are required to
issue the Program Command:
During Program operations the memory will accept the Read Status Register command and
the Program/Erase Suspend command. Typical Program times are given in
Program/Erase times and endurance
Programming aborts if Reset goes to V
program operation is aborted, the block containing the memory location must be erased and
reprogrammed.
See
the Program command.
Appendix
Appendix
The first bus cycle sets up the Erase command.
The second latches the block address in the internal state machine and starts the
Program/Erase Controller.
The first bus cycle sets up the Program command.
The second latches the Address and the Data to be written and starts the
Program/Erase Controller.
C,
C,
Figure 22: Erase flowchart and pseudo
Table 18: Program flowchart and pseudo
Table 8: Program/Erase times and endurance
IL
. As data integrity cannot be guaranteed when the Erase
cycles.
IL
. As data integrity cannot be guaranteed when the
code, for a suggested flowchart for
code, for the flowchart for using
cycles.
Command Interface
Table 8:
21/76

Related parts for M28W640FSU70ZA6