PCA8574TS,112 NXP Semiconductors, PCA8574TS,112 Datasheet - Page 11

IC I/O EXPANDER I2C 8B 20SSOP

PCA8574TS,112

Manufacturer Part Number
PCA8574TS,112
Description
IC I/O EXPANDER I2C 8B 20SSOP
Manufacturer
NXP Semiconductors
Datasheet

Specifications of PCA8574TS,112

Package / Case
20-SSOP
Interface
I²C
Number Of I /o
8
Interrupt Output
Yes
Frequency - Clock
400kHz
Voltage - Supply
2.3 V ~ 5.5 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Includes
POR
Logic Family
PCA8574
Number Of Lines (input / Output)
8.0 / 8.0
Operating Supply Voltage
2.3 V to 5.5 V
Power Dissipation
400 mW
Operating Temperature Range
- 40 C to + 85 C
Input Voltage
5.5 V
Logic Type
I/O Expander
Maximum Clock Frequency
400 KHz
Mounting Style
SMD/SMT
Number Of Input Lines
8.0
Number Of Output Lines
8.0
Output Current
50 mA
Output Voltage
5.5 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
568-4242-5
935283487112
PCA8574TS
NXP Semiconductors
PCA8574_PCA8574A_2
Product data sheet
Fig 13. System configuration
SDA
SCL
TRANSMITTER/
RECEIVER
MASTER
9.3 Acknowledge
The number of data bytes transferred between the START and the STOP conditions from
transmitter to receiver is not limited. Each byte of eight bits is followed by one
acknowledge bit. The acknowledge bit is a HIGH level put on the bus by the transmitter,
whereas the master generates an extra acknowledge related clock pulse.
A slave receiver which is addressed must generate an acknowledge after the reception of
each byte. Also a master must generate an acknowledge after the reception of each byte
that has been clocked out of the slave transmitter. The device that acknowledges has to
pull down the SDA line during the acknowledge clock pulse, so that the SDA line is stable
LOW during the HIGH period of the acknowledge related clock pulse; set-up and hold
times must be taken into account.
A master receiver must signal an end of data to the transmitter by not generating an
acknowledge on the last byte that has been clocked out of the slave. In this event, the
transmitter must leave the data line HIGH to enable the master to generate a STOP
condition.
Fig 14. Acknowledgement on the I
RECEIVER
SLAVE
SCL from master
by transmitter
data output
by receiver
data output
TRANSMITTER/
Rev. 02 — 14 May 2007
RECEIVER
condition
START
SLAVE
S
Remote 8-bit I/O expander for I
2
C-bus
TRANSMITTER
1
MASTER
2
TRANSMITTER/
RECEIVER
MASTER
acknowledgement
not acknowledge
SLAVE
clock pulse for
acknowledge
PCA8574/74A
8
2
C-bus with interrupt
MULTIPLEXER
© NXP B.V. 2007. All rights reserved.
002aaa987
I
2
9
C-BUS
002aaa966
11 of 27

Related parts for PCA8574TS,112