3F88L-CR002C Omron, 3F88L-CR002C Datasheet - Page 138

no-image

3F88L-CR002C

Manufacturer Part Number
3F88L-CR002C
Description
CABLE RESOLVER FOR RS17/T 2M
Manufacturer
Omron
Datasheet

Specifications of 3F88L-CR002C

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
3F88LCR002C
Operation
D Changes in Display after Teaching Inputs
D Deleting Cam Program Steps
• Perform the following operation to delete steps in an existing cam program for a particular cam num-
• Display the step to be deleted. (Press the Set Key to display the steps in order.)
• Press the the Clear Key while pressing the ON/OFF Switching Key. The ON and OFF angles will flash
• Press the Set Key to delete the data. The displays will change to “-- -- --” and “-- -- --.”
• If the Clear Key is pressed when the step data is ready to be deleted, the delete operation will be can-
Note The “-- -- --” and “-- -- --” displayed after the step has been deleted indicate the next status after the
Relationship between Teaching and Various Compensation Functions
3-86
ber.
(indicating that the step data is ready to be deleted.)
celed, and the display will return to the original display.
S If the teaching function is used while other compensation functions are set, the present angle as
S When using compensation functions, perform teaching after these functions have been changed
adjusted by the compensation function will be read as ON angle or OFF angle data.
to the “enabled” status.
last step. Therefore, press the Set Key while pressing the ON/OFF Switching Key to display the
ON and OFF angles for step 1.
Origin compensation (origin shift):
Backlash compensation:
Advance angle compensation:
Teaching (bank number 1, cam number 1)
Teaching (bank number 1, cam number 1)
Step data ready to be deleted
ON angle input status
Refer to 3-6-4 Origin Compensation and Origin Shift.
Refer to 3-6-5 Backlash Compensation.
Refer to 3-6-6 Advance Angle Compensation.
Deleting step data
OFF angle input status
Chapter 3