C200H-ATTA3 Omron, C200H-ATTA3 Datasheet - Page 44

no-image

C200H-ATTA3

Manufacturer Part Number
C200H-ATTA3
Description
I/O LOCK BRACKT 10-SLOT
Manufacturer
Omron
Datasheet

Specifications of C200H-ATTA3

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
C200HATTA3
I/O Units
2-5-3 High-density I/O Units Classified as Special I/O Units
Setting the Unit Number
Setting the DIP Switch
30
TTL Input Unit
DC Input Unit
TTL Output Unit
Transistor Output Unit
TTL I/O Unit
DC Input/Transistor
O
Output Unit
1
2
3
4
5
6
Pin
p
Operating mode
High-speed input
High-speed input
minimum pulse width
Input response time
Data output mode
Not used.
U i
Unit
Function
5 VDC, 32 inputs
24 VDC; 32 inputs
5 VDC, 32 outputs
24 VDC; 32 outputs
5 VDC, 16 inputs, 16 outputs
12 VDC; 16 inputs, 16 outputs
24 VDC; 16 inputs, 16 outputs
1
4
3
Note Refer to Optional Products, Appendix A Standard Models for a list of external
Note
2
C200H-OD501/OD215
C200H-MD501/MD115/MD215
C200H-ID501/ID215
C200H-MD501/MD115/MD215
C200H-ID501/ID215
C200H-MD501/MD115/MD215
C200H-ID501/ID215
C200H-MD501/MD115/MD215
C200H-OD501/OD215
---
Specifications
Some High-density I/O Units are classified as Special I/O Units. Up to 10 Special
I/O Units can be connected to a PC. The Units have two 24-pin connectors. In
general, these Units control 32 I/O points, although some Units can control 128
I/O points when set for dynamic operation.
Refer to Appendix B Specifications for detailed specifications and dimensions of
the Units.
connectors.
High-density I/O Units are each allocated 10 I/O words in the IR Area (IR 100 to
IR 199) by setting the unit number switch on the front of each Unit. The 10 words
begin with n, where n = IR 100 + 10 × unit number. For example, a Special I/O
Unit with a unit number of 3 would be allocated IR 130 to IR 139.
Always turn the PC power off before changing a Unit’s unit number. The new unit
number (0 to 9) will not be recognized unless the PC has been turned off.
The operation of High-density I/O Units is controlled by setting the pins of the
DIP switch on the back panel. The following table shows the function of each pin
and applicable Units.
1. Used in the C200H-MD501/MD115/MD215 only when pin 1 is OFF, setting
2. Used in the C200H-ID501/215, C200H-MD501/MD215/MD115/MD215
3. Sets the input response time for normal inputs. When pin 2 is ON, CN2 08 to
the Unit to static mode.
only when pin 2 is ON, setting the Unit to High-speed input mode.
15 are pulse-catch inputs. Other inputs can be used as normal inputs.
Applicable Units
pp
C200H-ID501
C200H-ID215
C200H-OD501
C200H-OD215
C200H-MD501
C200H-MD115
C200H-MD215
Model Number
128 dynamic outputs
128 dynamic inputs
Inputs 08 to 15 of CN2
are high-speed inputs.
Inputs 08 to 15 of CN2
are high-speed inputs.
4 ms
15 ms max.
Positive logic
---
8 pts can be set as high-speed inputs.
Can be set for 128 dynamic outputs.
8 pts can be set as high-speed inputs.
Can be set for 128 dynamic inputs.
Can be set for 128 dynamic inputs.
ON
p
Setting
Remarks
32 outputs
16 inputs, 16 outputs
Normal inputs
Normal inputs
1 ms
2.5 ms max.
Negative logic
---
g
p
Section 2-5
OFF
p