XW2Z-100J-A27 Omron, XW2Z-100J-A27 Datasheet - Page 6

no-image

XW2Z-100J-A27

Manufacturer Part Number
XW2Z-100J-A27
Description
SERVO RELAY UNIT CABLES 1M
Manufacturer
Omron
Datasheet

Specifications of XW2Z-100J-A27

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
XW2Z100JA27
Performance Specifications
*1. The following time must be added when using EtherNet/IP tag data links for the CJ2M-CPU3@.
*2. Force-setting/resetting bits in the EM Area is possible only for banks specified for the EM Area force-set/reset function.
User Memory
I/O Bits
Processing
Speed
Maximum Number of Connectable Units
Maximum Number of Expansion Racks
CIO Area
Work Area
Holding Area
Auxiliary Area
Temporary Area
Timer Area
Counter Area
DM Area
EM Area
Index Registers
Cyclic Task Flag Area
Memory Card
Operating Modes
The following time must be added when using Pulse I/O Modules with a CJ2M CPU Unit:
100 μs + (Number of words transferred × 1.8 μs)
10 μs × Number of Pulse I/O Modules
Overhead Processing Time *1
Execution Time
Interrupts
Basic I/O Units
Special I/O Units
CPU Bus Units
Pulse I/O Modules
Slots for which interrupts can be
used
I/O Area
Link Area
CPU Bus Unit Area
Special I/O Unit Area
Pulse I/O Area
Serial PLC Link Words
DeviceNet Area
Internal I/O Area
Force-S/R Enabled Banks *2
Items
I/O Interrupts and
External Interrupts
Scheduled
Interrupts
5K steps
2,560 bits
Normal Mode:
CJ2M-CPU3@: 270 μs
CJ2M-CPU1@: 160 μs
Basic Instructions
Special Instructions : 0.06 μs min.
Interrupt task startup time: 31 μs
Return time to cyclic task : 10 μs
Minimum time interval : 0.4 ms (set in 0.1 ms increments)
Interrupt task startup time: 30 μs
Return time to cyclic task : 11 μs
Total per CPU Rack or Expansion Rack: 10 Units max.;
Total per PLC: 40 Units max.
No limit
However, a maximum of two CJ1W-INT01 Interrupt Input Units can be mounted.
Units for up to 96 unit numbers can be mounted. (Unit numbers run from 0 to 95. Units are allocated between
1 and 8 unit numbers.)
CJ2M-CPU3@: 15 Units max.
CJ2M-CPU1@: 16 Units max.
2 Units max. *
* Supported only by CJ2M CPU Units with unit version 2.0 or later. A Pulse I/O Module must be mounted.
Slots 0 to 4 on CPU Rack
3 max.
2,560 bits (160 words) : Words CIO 0000 to CIO 0159
3,200 bits (200 words) : Words CIO 1000 to CIO 1199
6,400 bits (400 words) : Words CIO 1500 to CIO 1899
15,360 bits (960 words): Words CIO 2000 to CIO 2959
20 inputs, 12 outputs (CIO 2960 to CIO 2963)
1,440 bits (90 words)
9,600 bits (600 words) : Words CIO 3200 to CIO 3799
3,200 bits (200 words) : Words CIO 1300 to CIO 1499 (Cannot be used for external I/O.)
37,504 bits (2,344 words): Words CIO 3800 to CIO 6143 (Cannot be used for external I/O.)
8,192 bits (512 words): Words W000 to W511 (Cannot be used for external I/O.)
8,192 bits (512 words): Words H000 to H511
Bits in this area maintain their ON/OFF status when PLC is turned OFF or operating mode is changed.
Words H512 to H1535: These words can be used only for function blocks. They can be used only for function
block instances (i.e., they are allocated only for internal variables in function blocks).
Read-only: 31,744 bits (1,984 words)
Read/write: 16,384 bits (1,024 words) in words A448 to A1471 *
* A960 to A1471 and A10000 to A11535 cannot be accessed by CPU Bus Units, Special I/O Units, PTs, and
16 bits: TR0 to TR15
4,096 timer numbers (T0000 to T4095 (separate from counters))
4,096 counter numbers (C0000 to C4095 (separate from timers))
32k words *
* Bits in the EM Area can be addressed either by bit or by word. These bits cannot be addressed by CPU Bus
32k words/bank × 4 banks max.: E00_00000 to E3_32767 max. *
* Bits in the EM Area can be addressed either by bit or by word. These bits cannot be addressed by CPU Bus
32K words × 1 bank
Bank 0 hex
IR0 to IR15
These are special registers for storing PLC memory addresses for indirect addressing. (Index Registers can
be set so that they are unique in each task or so that they are shared by all tasks.)
128 flags
128 MB, 256 MB, or 512 MB
PROGRAM Mode: Programs are not executed. Preparations can be executed prior to program execution in
MONITOR Mode: Programs are executed, and some operations, such as online editing, and changes to
RUN Mode:
• 7,168 bits (448 words): Words A0 to A447
• 24,576 bits (1,536 words): Words A10000 to A11535 *
• DM Area words for Special I/O Units: D20000 to D29599 (100 words × 96 Units)
• DM Area words for CPU Bus Units: D30000 to D31599 (100 words × 16 Units)
Support Software that do not specifically support the CJ2 CPU Units.
Units, Special I/O Units, PTs, and Support Software that do not specifically support the CJ2 CPU Units.
Units, Special I/O Units, PTs, and Support Software that do not specifically support the CJ2 CPU Units.
CPU11/31
this mode.
present values in I/O memory, are enabled in this mode.
Programs are executed. This is the normal operating mode.
: 0.04 μs min.
10K steps
: Words CIO 3100 to CIO 3189
CPU12/32
CJ2M-CPU3@/-CPU1@/-MD21@
20K steps
CPU13/33
CJ2M-
30K steps
32K words × 4 banks
Bank 0 to 3 hex
CPU14/34
60K steps
CPU15/35
6