R88A-PX5052 Omron, R88A-PX5052 Datasheet - Page 378
R88A-PX5052
Manufacturer Part Number
R88A-PX5052
Description
REACTOR R88D-WN02L/08H ML2
Manufacturer
Omron
Datasheet
1.R88A-TK05W.pdf
(412 pages)
Specifications of R88A-PX5052
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
R88APX5052
- Current page: 378 of 412
- Download datasheet (7Mb)
• When using the Servo Driver under the continuous operation mode, cool the Servo Driver with fans
• The life of aluminum analytical capacitors is greatly affected by the ambient operating temperature.
• If the Servomotor or Servo Driver is not to be used for a long time, or if they are to be used under
5-46
Troubleshooting
and air conditioners to maintain an ambient operating temperature below 40 ° C.
Generally speaking, an increase of 10 ° C in the ambient operating temperature will reduce capacitor
life by 50%. We recommend that ambient operating temperature be lowered and the power supply
time be reduced as much as possible to lengthen the maintenance times for Servo Drivers.
conditions worse than those described above, a periodic inspection schedule of five years is recom-
mended. Please consult with OMRON to determine whether or not components need to be
replaced.
Absolute encoder backup battery: 50,000 hours, at an ambient Servo Driver operating tempera-
ture of 20 ° C.
Chapter 5