B7AP-M1C Omron, B7AP-M1C Datasheet

no-image

B7AP-M1C

Manufacturer Part Number
B7AP-M1C
Description
COUPLER INDUCT PWR MOVING UNIT
Manufacturer
Omron
Datasheet

Specifications of B7AP-M1C

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
B7APM1C
Allows Wireless Transmission of
ON/OFF Signals from Input Devices
and Power to Input Devices
H
H
H
Ordering Information
Note: The B7AP-S1 Power Coupler has a gauge that is used to adjust the transmission distance between the B7AP-S1 and B7AP-M1
Classification
Stationary Unit
Moving Unit
Inductive Power Couplers
Use the electromagnetic coupler to
transmit input signals to the B7A Output
Unit
Supplies power to the B7A Input Unit,
which means it does not require an
independent power supply
Wireless signal and power transmission
through a nonmetal object (such as
plastic or glass) is possible
Power Couplers.
Appearance
M30
M30
R
Transmission distance
(couplers)
(0.32 in ±0.06 in)
8±1.5 mm
I/O delay
Typical: 19.2 ms
Max.:
31 ms
Part number
B7AP-S1 (See Note.)
B7AP-M1
B7AP

B7AP-M1C Summary of contents

Page 1

... Ordering Information Classification Appearance Stationary Unit M30 Moving Unit M30 Note: The B7AP-S1 Power Coupler has a gauge that is used to adjust the transmission distance between the B7AP-S1 and B7AP-M1 Power Couplers. Transmission distance I/O delay (couplers) Typical: 19.2 ms 8±1.5 mm Max (0.32 in ± ...

Page 2

... Refer to Power Supplies in Operation Section of this data sheet. 2. The maximum I/O points are the same as the maximum input points of the B7A Input Unit connected to the B7AP-M1. 3. PLCs and three-wire sensors can be connected only if the B7A Input and Output Units are each connected with an independent power supply ...

Page 3

... N (5 kgf) (11 lbs (400 kgf S cm) (28 lbf) IEC IP67 2 m (78.7 in) Approx. 300 g (10.58 oz) Radiated Emissions: EN55022 class A Radiated Immunity: prEN50082-2 Electrostatic Discharge: prEN50082-2 Burst Transients: prEN50082-2 UL508 Conforms to EN50081-2, EN50082-2 12 VDC ±10 B7AP B7AP-M1 --- --- Approx. 230 g (8.11 oz) 3 ...

Page 4

... Unit (96 m max.) Total length: 500 m max. Note: 1. The thickness of the extension cable for the B7AP-S1 or B7AP-M1 Power Coupler must be 0.75 mm min. 2. For transmitting signals only, the brown lead wire of the B7AP-M1 Power Coupler must not be used. Insulate the brown lead wire with insulation tape so that the brown wire will not come in contact with any lead wire ...

Page 5

... Lit when power is supplied to the Power Coupler. Not lit when power is not supplied to the Power Coupler. Lit when the B7AP-M1 and B7AP-S1 Power Couplers are properly set for wireless signal or power transmission at a transmission distance of 8 ±1.5 mm. (0.32 ±0.06). Not lit when the B7AP-M1 and B7AP-S1 Power Couplers are not properly set for wireless signal or power transmission, or the B7AP-M1 Power Coupler has excessive loads ...

Page 6

... Power Couplers operate normally before they are put in actual operation. Correct Power or high-tension line Do not subject the head of the B7AP-S1 or B7AP-M1 Power Coupler to excessive shock with hard objects. Do not use the B7AP-S1 or B7AP-M1 Power Coupler outdoors unless it is properly protected. ...

Page 7

... J TRANSMISSION DISTANCE FOR STABLE SIGNAL AND POWER TRANS- MISSION The B7AP-S1 Power Coupler has a gauge that is used to adjust the transmission distance between the B7AP-S1 and B7AP-M1 Power Couplers. Use the gauge to adjust the transmission distance to 8 mm, make sure that the green operation indicator of the B7AP-M1 Power Coupler is lit, and the B7A Output Unit has no error output before operating the Power Couplers ...

Page 8

... OMRON ELECTRONICS LLC One East Commerce Drive Schaumburg, IL 60173 1-800-55-OMRON Cat. No. CEDSAX4 11/01 OMRON ON- - LINE Global - - http://www.omron.com USA - - http://www.omron.com/oei Canada - - http://www.omron.com/oci Specifications subject to change without notice. B7AP OMRON CANADA, INC. 885 Milner Avenue Scarborough, Ontario M1B 5V8 416-286-6465 Printed in U.S.A . ...