B7AP-M1C Omron, B7AP-M1C Datasheet - Page 7

no-image

B7AP-M1C

Manufacturer Part Number
B7AP-M1C
Description
COUPLER INDUCT PWR MOVING UNIT
Manufacturer
Omron
Datasheet

Specifications of B7AP-M1C

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
B7APM1C
J TRANSMISSION DISTANCE FOR
The B7AP-S1 Power Coupler has a gauge that is used to adjust
the transmission distance between the B7AP-S1 and B7AP-M1
Power Couplers. Use the gauge to adjust the transmission
distance to 8 mm, make sure that the green operation indicator of
the B7AP-M1 Power Coupler is lit, and the B7A Output Unit has
no error output before operating the Power Couplers.
J MONITORING TRANSMISSION STATUS
Judge from the power supply/error indicator and error output of
the B7A Output Unit whether the B7AP-S1 and B7AP-M1 Power
Couplers are facing each other correctly.
The error output of the B7A Output Unit will be ON when the
B7AP-S1 and B7AP-M1 Power Couplers are not facing each
other correctly.
J MINIMUM DISTANCE BETWEEN POWER
When mounting the B7AP-S1 and B7AP-M1 Power Couplers in
parallel, refer to the following table. Keep at least the specified
minimum distance between adjacent Power Couplers for proper
heat radiation by considering the temperature rise (approximately
20°C) of the B7AP-S1 Power Couplers in operation.
B7AP
Item
STABLE SIGNAL AND POWER TRANS-
MISSION
COUPLERS MOUNTED IN PARALLEL
Gauge
8 mm
B7AP-S1
60 mm (2.36 in)
Operation
indicator
B7AP-M1
60 mm (2.36 in)
J EFFECTS OF SURROUNDING METAL
The B7AP Power Coupler may malfunction when affected by
surrounding metal. When mounting the B7AP within a metal
panel, ensure that the clearances given in the following table are
maintained. Be sure to check in advance that the B7AP operates
correctly.
J MAINTENANCE
Regularly check these items for the stable operation of the
B7AP-S1 and B7AP-M1 Power Couplers:
Item
d
D
n
The mounting positions and the tightening of the mounting
nuts.
The tightening, contacts, and breaking of the lead wires.
Dust accumulation on the heads.
The ambient operating temperature and other operating
conditions.
The transmission distance.
B7AP-S1
20 mm (0.79 in)
60 mm dia. (2.36 in)
20 mm (0.79 in)
60 mm (2.36 in)
d dia.
B7AP-M1
20 mm (0.79 in)
60 mm dia. (2.36 in)
20 mm (0.79 in)
60 mm (2.36 in)
B7AP
7