166981-005 FCI, 166981-005 Datasheet - Page 17

no-image

166981-005

Manufacturer Part Number
166981-005
Description
Manufacturer
FCI
Datasheet

Specifications of 166981-005

Lead Free Status / Rohs Status
Not Compliant
11.0 ASSEMBLY OF COMPONENTS AFTER WIRE INSERTION
TITLE
Specification of Requirements for Cable Preparation, Wire Termination and
Copyright FCI
Form E-3334
Rev E
11.1
Assembly of Connectors Using 72392-type Contacts
72476 and 72477 type Metral™ Unshielded Connectors
11.1.1 Assembly of Covers to Connector Sub-Assemblies
The two cover halves are pressed together trapping the connector sub-assemblies with the
inserted cable wires between the two halves. The connector sub-assemblies must be aligned so
that the side with the smaller diameter but longer stud faces the latch side cover. The force
required to press the two halves together is such that a fixture is needed. The covers can be
disassembled and reassembled up to three times if repairs are needed. After assembly check to
see that the small separator ribs on the covers that go between the insulators ( connector sub-
assemblies ) are actually between the insulators and not smashed down under the side of the
insulators.
FCI Part No.
HT-0520
Figure 14 Assembly of Covers - 72476 type Connectors
TYPE
APPLICATION SPECIFICATION
Drawing No.
415810-001
PDM: Rev:J
Cover Assembly Fixture
Description
NUMBER
PAGE
AUTHORIZED BY
STATUS
STATUS:
J.R. Volstorf
17 of 29
UNRESTRICTED
Released
GS-20-002
Instructions
415835-001
REVISION
DATE
25-Apr-06
Printed: Nov 27, 2010
J