AT24C16A-10TU-2.7 Atmel, AT24C16A-10TU-2.7 Datasheet - Page 2

AT24C16A-10TU-2.7

Manufacturer Part Number
AT24C16A-10TU-2.7
Description
Manufacturer
Atmel
Datasheet

Specifications of AT24C16A-10TU-2.7

Density
16Kb
Interface Type
Serial (2-Wire)
Organization
2Kx8
Access Time (max)
900ns
Frequency (max)
400KHz
Write Protection
Yes
Data Retention
100Year
Operating Supply Voltage (typ)
3.3/5V
Package Type
TSSOP
Operating Temp Range
-40C to 85C
Supply Current
3mA
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (max)
5.5V
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Pin Count
8
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT24C16A-10TU-2.7
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Absolute Maximum Ratings*
Block Diagram
Pin Description
2
Operating Temperature.................................. -55 C to +125 C
Storage Temperature ..................................... -65 C to +150 C
Voltage on Any Pin
with Respect to Ground .....................................-1.0V to +7.0V
Maximum Operating Voltage .......................................... 6.25V
DC Output Current........................................................ 5.0 mA
AT24C02A/04A/08A/16A
SERIAL CLOCK (SCL): The SCL input is used to positive edge clock data into each
EEPROM device and negative edge clock data out of each device.
SERIAL DATA (SDA): The SDA pin is bidirectional for serial data transfer. This pin is
open-drain driven and may be wire-ORed with any number of other open-drain or open
collector devices.
DEVICE/PAGE ADDRESSES (A2, A1, A0): The A2, A1 and A0 pins are device
address inputs that must be hard wired for the AT24C02A. As many as eight 2K devices
may be addressed on a single bus system (device addressing is discussed in detail
under the Device Addressing section).
The AT24C04A uses the A2 and A1 inputs for hard wire addressing and a total of four
4K devices may be addressed on a single bus system. The A0 pin is a no-connect.
*NOTICE:
Stresses beyond those listed under “Absolute
Maximum Ratings” may cause permanent dam-
age to the device. This is a stress rating only and
functional operation of the device at these or any
other conditions beyond those indicated in the
operational sections of this specification is not
implied. Exposure to absolute maximum rating
conditions for extended periods may affect device
reliability.
0976L–SEEPR–1/04

Related parts for AT24C16A-10TU-2.7