AT24C16A-10TU-2.7 Atmel, AT24C16A-10TU-2.7 Datasheet - Page 6

AT24C16A-10TU-2.7

Manufacturer Part Number
AT24C16A-10TU-2.7
Description
Manufacturer
Atmel
Datasheet

Specifications of AT24C16A-10TU-2.7

Density
16Kb
Interface Type
Serial (2-Wire)
Organization
2Kx8
Access Time (max)
900ns
Frequency (max)
400KHz
Write Protection
Yes
Data Retention
100Year
Operating Supply Voltage (typ)
3.3/5V
Package Type
TSSOP
Operating Temp Range
-40C to 85C
Supply Current
3mA
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (max)
5.5V
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Pin Count
8
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT24C16A-10TU-2.7
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Device Operation
CLOCK and DATA TRANSITIONS: The SDA pin is normally pulled high with an exter-
nal device. Data on the SDA pin may change only during SCL low time periods (refer to
Data Validity timing diagram). Data changes during SCL high periods will indicate a start
or stop condition as defined below.
START CONDITION: A high-to-low transition of SDA with SCL high is a start condition
which must precede any other command (refer to Start and Stop Definition timing
diagram).
STOP CONDITION: A low-to-high transition of SDA with SCL high is a stop condition.
After a read sequence, the stop command will place the EEPROM in a standby power
mode (refer to Start and Stop Definition timing diagram).
ACKNOWLEDGE: All addresses and data words are serially transmitted to and from
.
the EEPROM in 8 bit words
The EEPROM sends a zero to acknowledge that it has
received each word. This happens during the ninth clock cycle.
STANDBY MODE: The AT24C02A/04A/08A/16A features a low power standby mode
which is enabled: (a) upon power-up and (b) after the receipt of the STOP bit and the
completion of any internal operations.
MEMORY RESET: After an interruption in protocol, power loss or system reset, any
2-wire part can be reset by following these steps: (a) Clock up to 9 cycles, (b) look for
SDA high in each cycle while SCL is high and then (c) create a start condition as SDA is
high.
AT24C02A/04A/08A/16A