LM81CIMT-3 National Semiconductor, LM81CIMT-3 Datasheet - Page 20

LM81CIMT-3

Manufacturer Part Number
LM81CIMT-3
Description
Manufacturer
National Semiconductor
Datasheet

Specifications of LM81CIMT-3

Monitored Voltage 1 (typ)
2.5/3.3/5/12V
Battery Backup Switching
No
Watchdog Timer
Yes
Chip Enable Signals
No
Manual Reset
No
Package Type
TSSOP
Operating Supply Voltage (min)
2.8V
Operating Supply Voltage (max)
3.8V
Operating Temp Range
-40C to 125C
Operating Temperature Classification
Automotive
Power Fail Detection
No
Mounting
Surface Mount
Pin Count
24
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LM81CIMT-3
Manufacturer:
NS
Quantity:
1
Part Number:
LM81CIMT-3
Manufacturer:
national
Quantity:
2
Part Number:
LM81CIMT-3
Manufacturer:
NS/国半
Quantity:
20 000
Company:
Part Number:
LM81CIMT-3
Quantity:
2 825
Company:
Part Number:
LM81CIMT-3
Quantity:
2 825
Part Number:
LM81CIMT-3/NOPB
Manufacturer:
RENESAS
Quantity:
2 000
www.national.com
Functional Description
8.2 Temperature Interrupts
INT and T_CRIT_A outputs are provided for temperature
interrupt. Temperature interrupts have a normal and an ex-
tended option of operation. Each option has three different
modes of operation: Repetitive Interrupt, One-Time Interrupt
and Comparator.
Normal Repetitive Interrupt Mode is shown in Figure 11
and operates in the following way: T_CRIT_A is disabled.
Exceeding T
indefinitely until reset by reading Interrupt Status Register 1.
Once reset if the temperature remains above the T
setpoint the interrupt will again be activated at the comple-
tion of another conversion cycle. If temperature is less than
or equal to T
*
Note: Interrupt resets occur only when interrupt Status Register 1 is read.
FIGURE 11. Normal Repetitive Interrupt Response
HIGH
HIHYST
causes an interrupt that will remain active
the interrupt will not be activated.
Diagram
(Continued)
DS100072-16
HIHYST
20
Normal One-Time Interrupt Mode is shown in Figure 12
and operates in the following way: T_CRIT_A is disabled.
Exceeding T
indefinitely until reset by reading Interrupt Status Register 1.
Another interrupt will not occur until the temperature drops to
less than or equal to T
a subsequent conversion. After power up this mode is se-
lected as default.
*
Normal Comparator Mode is shown in Figure 13 and op-
erates in the following way: T_CRIT_A is disabled. Exceed-
ing T
the temperature is less than or equal to T
disabled.
*
Note: Interrupt resets occur only when interrupt Status Register 1 is read.
Note: Interrupt resets occur only when interrupt Status Register 1 is read.
FIGURE 12. One-Time Interrupt Response Diagram
HIGH
FIGURE 13. Normal Comparator Mode
causes an interrupt that will remain activated until
HIGH
causes an interrupt that will remain active
HIHYST
and then exceeds T
HIGH
DS100072-18
DS100072-17
HIGH
. T
LOW
during
is

Related parts for LM81CIMT-3