LM63CIMA National Semiconductor, LM63CIMA Datasheet - Page 24

no-image

LM63CIMA

Manufacturer Part Number
LM63CIMA
Description
Manufacturer
National Semiconductor
Datasheet

Specifications of LM63CIMA

Temperature Sensor Function
Temp Sensor
Interface Type
Serial (2-Wire)
Output Type
Digital
Package Type
SOIC N
Operating Temperature (min)
0C
Operating Temperature (max)
85C
Operating Temperature Classification
Commercial
Operating Supply Voltage (min)
3V
Operating Supply Voltage (typ)
3.3V
Operating Supply Voltage (max)
3.6V
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LM63CIMA
Manufacturer:
NS
Quantity:
8
Part Number:
LM63CIMA
Manufacturer:
NS
Quantity:
300
Part Number:
LM63CIMA
Manufacturer:
NS/国半
Quantity:
20 000
Part Number:
LM63CIMAX
Manufacturer:
RENESAS
Quantity:
5 220
Part Number:
LM63CIMAX
Manufacturer:
NSC
Quantity:
8 000
Part Number:
LM63CIMAX
Manufacturer:
NS/国半
Quantity:
20 000
Company:
Part Number:
LM63CIMAX
Quantity:
2 000
Company:
Part Number:
LM63CIMAX
Quantity:
2 500
Part Number:
LM63CIMAX-NOPB
Manufacturer:
NS/国半
Quantity:
20 000
Company:
Part Number:
LM63CIMAX/NOPB
Quantity:
25 000
www.national.com
PWM
Freq
[4:0]
3.0 Application Notes
3.1 FAN CONTROL DUTY CYCLE VS. REGISTER SETTINGS AND FREQUENCY
3.1.1 Computing Duty Cycles for a Given Frequency
Select a PWM Frequency from the first column corresponding
to the desired actual frequency in columns 6 or 7. Note the
PWM Value for 100% Duty Cycle.
Find the Duty Cycle by taking the PWM Value of Register 4C
and computing:
4D
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
0
1
2
3
4
5
6
7
8
9
Resolution,
Step
16.7
12.5
10.0
8.33
7.14
6.25
5.56
5.00
4.54
4.16
3.85
3.57
3.33
3.13
2.94
2.78
2.63
2.50
2.38
2.27
2.17
2.08
2.00
1.92
1.85
1.79
1.72
1.67
1.61
50
25
%
for 100%
4D [5:0]
Value
PWM
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
46
48
50
52
54
56
58
60
62
2
4
6
8
4C [5:0] for
about 75%
Value
PWM
11
12
14
15
17
18
20
21
23
24
26
27
29
30
32
33
35
36
38
39
41
42
44
45
47
1
3
5
6
8
9
Address 0 is mapped to Address 1
4C [5:0]
for 50%
Value
PWM
24
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
1
2
3
4
5
6
7
8
9
Example: For a PWM Frequency of 24, a PWM Value at 100%
= 48 and PWM Value actual = 28, then the Duty Cycle is
(28/48) × 100% = 58.3%.
Clock, kHz
360 kHz
Internal
Freq at
PWM
180.0
90.00
60.00
45.00
36.00
30.00
25.71
22.50
20.00
18.00
16.36
15.00
13.85
12.86
12.00
11.25
10.59
10.00
9.47
9.00
8.57
8.18
7.82
7.50
7.20
6.92
6.67
6.42
6.21
6.00
5.81
Clock, Hz
Internal
1.4 kHz
Freq at
PWM
703.1
351.6
234.4
175.8
140.6
117.2
100.4
87.9
78.1
70.3
63.9
58.6
54.1
50.2
46.9
43.9
41.4
39.1
37.0
35.2
33.5
32.0
30.6
29.3
28.1
27.0
26.0
25.1
24.2
23.4
22.7
75% is Selected
Cycle, % When
Actual Duty
77.27
75.00
76.92
75.00
76.67
75.00
76.47
75.00
76.32
75.00
76.19
75.00
76.09
75.00
76.00
75.00
75.93
75.00
75.86
75.00
75.81
50.0
75.0
83.3
75.0
80.0
75.0
78.6
75.0
77.8
75.0