XC3S100E-5TQ144C Xilinx Inc, XC3S100E-5TQ144C Datasheet - Page 141

no-image

XC3S100E-5TQ144C

Manufacturer Part Number
XC3S100E-5TQ144C
Description
FPGA Spartan®-3E Family 100K Gates 2160 Cells 657MHz 90nm (CMOS) Technology 1.2V 144-Pin TQFP
Manufacturer
Xilinx Inc
Datasheet

Specifications of XC3S100E-5TQ144C

Package
144TQFP
Family Name
Spartan®-3E
Device Logic Cells
2160
Device Logic Units
240
Device System Gates
100000
Number Of Registers
1920
Maximum Internal Frequency
657 MHz
Typical Operating Supply Voltage
1.2 V
Maximum Number Of User I/os
108
Ram Bits
73728
Re-programmability Support
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
XC3S100E-5TQ144C
Manufacturer:
XILINX
0
Part Number:
XC3S100E-5TQ144C
Manufacturer:
XILINX/赛灵思
Quantity:
20 000
18 x 18 Embedded Multiplier Timing
Table 102: 18 x 18 Embedded Multiplier Timing
DS312-3 (v3.8) August 26, 2009
Product Specification
Notes:
1.
2.
3.
Combinatorial Delay
T
Clock-to-Output Times
T
T
T
Setup Times
T
T
T
Hold Times
T
T
T
Clock Frequency
F
MULT
MSCKP_P
MSCKP_A
MSCKP_B
MSDCK_P
MSDCK_A
MSDCK_B
MSCKD_P
MSCKD_A
MSCKD_B
MULT
Symbol
Combinatorial delay is less and pipelined performance is higher when multiplying input data with less than 18 bits.
The PREG register is typically used in both single-stage and two-stage pipelined multiplier implementations.
Input registers AREG or BREG are typically used when inferring a two-stage multiplier.
R
Combinatorial multiplier propagation delay from the A and B
inputs to the P outputs, assuming 18-bit inputs and a 36-bit
product (AREG, BREG, and PREG registers unused)
Clock-to-output delay from the active transition of the CLK
input to valid data appearing on the P outputs when using
the PREG register
Clock-to-output delay from the active transition of the CLK
input to valid data appearing on the P outputs when using
either the AREG or BREG register
Data setup time at the A or B input before the active
transition at the CLK when using only the PREG output
register (AREG, BREG registers unused)
Data setup time at the A input before the active transition at
the CLK when using the AREG input register
Data setup time at the B input before the active transition at
the CLK when using the BREG input register
Data hold time at the A or B input after the active transition
at the CLK when using only the PREG output register
(AREG, BREG registers unused)
Data hold time at the A input after the active transition at the
CLK when using the AREG input register
Data hold time at the B input after the active transition at the
CLK when using the BREG input register
Internal operating frequency for a two-stage 18x18
multiplier using the AREG and BREG input registers and
the PREG output register
(2)
Description
(1)
(2)
(3)
www.xilinx.com
(3)
(3)
(2)
(3)
(3)
3.54
0.20
0.35
0.03
0.04
Min
0.97
0
-
-
-
-5
DC and Switching Characteristics
4.34
Speed Grade
Max
0.98
4.42
270
-
-
-
-
-
-
(1)
3.98
0.23
0.39
0.04
0.05
Min
0.97
0
-
-
-
-4
4.88
Max
1.10
4.97
240
-
-
-
-
-
-
(1)
Units
MHz
ns
ns
ns
ns
ns
ns
ns
ns
ns
141