Specifications of M25P16-VMN6P

Cell Type
NOR
Density
16Mb
Access Time (max)
8ns
Interface Type
Serial (SPI)
Boot Type
Not Required
Address Bus
1b
Operating Supply Voltage (typ)
3.3V
Operating Temp Range
-40C to 85C
Package Type
SOIC N
Program/erase Volt (typ)
2.7 to 3.6V
Sync/async
Synchronous
Operating Temperature Classification
Industrial
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (max)
3.6V
Word Size
8b
Number Of Words
2M
Supply Current
12mA
Mounting
Surface Mount
Pin Count
8
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M25P16-VMN6P
Manufacturer:
Numonyx/ST Micro
Quantity:
83 042
Part Number:
M25P16-VMN6P
Manufacturer:
ST
0
Part Number:
M25P16-VMN6P
Manufacturer:
MICRON
Quantity:
20 000
Part Number:
M25P16-VMN6PBA
Manufacturer:
ST
0
Part Number:
M25P16-VMN6PBA
Manufacturer:
ST
Quantity:
20 000
6.11
Deep Power-down (DP)
Executing the Deep Power-down (DP) instruction is the only way to put the device in the
lowest consumption mode (the Deep Power-down mode). It can also be used as a software
protection mechanism, while the device is not in active use, as in this mode, the device
ignores all Write, Program and Erase instructions.
Driving Chip Select (S) High deselects the device, and puts the device in the Standby mode
(if there is no internal cycle currently in progress). But this mode is not the Deep Power-
down mode. The Deep Power-down mode can only be entered by executing the Deep
Power-down (DP) instruction, subsequently reducing the standby current (from I
as specified in
To take the device out of Deep Power-down mode, the Release from Deep Power-down and
Read Electronic Signature (RES) instruction must be issued. No other instruction must be
issued while the device is in Deep Power-down mode.
The Release from Deep Power-down and Read Electronic Signature (RES) instruction also
allows the electronic signature of the device to be output on Serial Data output (Q).
The Deep Power-down mode automatically stops at power-down, and the device always
powers up in the Standby mode.
The Deep Power-down (DP) instruction is entered by driving Chip Select (S) Low, followed
by the instruction code on Serial Data input (D). Chip Select (S) must be driven Low for the
entire duration of the sequence.
The instruction sequence is shown in
Chip Select (S) must be driven High after the eighth bit of the instruction code has been
latched in, otherwise the Deep Power-down (DP) instruction is not executed. As soon as
Chip Select (S) is driven High, it requires a delay of t
to I
Any Deep Power-down (DP) instruction, while an Erase, Program or Write cycle is in
progress, is rejected without having any effects on the cycle that is in progress.
Figure 18. Deep Power-down (DP) instruction sequence
S
C
D
CC2
and the Deep Power-down mode is entered.
Table
0
14).
1
2
Instruction
3
4
5
6
Figure
7
18.
DP
t
Standby mode
before the supply current is reduced
DP
Deep Power-down mode
CC1
AI03753D
to I
33/56