DS2155L+ Maxim Integrated Products, DS2155L+ Datasheet - Page 76

IC TXRX T1/E1/J1 1-CHIP 100-LQFP

DS2155L+

Manufacturer Part Number
DS2155L+
Description
IC TXRX T1/E1/J1 1-CHIP 100-LQFP
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS2155L+

Function
Single-Chip Transceiver
Interface
E1, HDLC, J1, T1
Number Of Circuits
1
Voltage - Supply
3.14 V ~ 3.47 V
Current - Supply
75mA
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
100-LQFP
Includes
BERT Generator and Detector, CMI Coder and Decoder, HDLC Controller
Product
Framer
Number Of Transceivers
1
Data Rate
64 Kbps
Supply Voltage (max)
3.465 V
Supply Voltage (min)
3.135 V
Supply Current (max)
75 mA (Typ)
Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
0 C
Mounting Style
SMD/SMT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Power (watts)
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
14.1 Line-Code Violation Count Register (LCVCR)
14.1.1 T1 Operation
T1 code violations are defined as bipolar violations (BPVs) or excessive 0s. If the B8ZS mode is set for
the receive side, then B8ZS codewords are not counted. This counter is always enabled; it is not disabled
during receive loss-of-synchronization (RLOS = 1) conditions.
count.
Table 14-A. T1 Line Code Violation Counting Options
14.1.2 E1 Operation
Either bipolar violations or code violations can be counted. Bipolar violations are defined as consecutive
marks of the same polarity. In this mode, if the HDB3 mode is set for the receive side, then HDB3
codewords are not counted as BPVs. If ERCNT.3 is set, then the LVC counts code violations as defined
in ITU O.161. Code violations are defined as consecutive bipolar violations of the same polarity. In most
applications, the framer should be programmed to count BPVs when receiving AMI code and to count
CVs when receiving HDB3 code. This counter increments at all times and is not disabled by loss-of-sync
conditions. The counter saturates at 65,535 and does not roll over. The bit-error rate on an E1 line would
have to be greater than 10
Table 14-B. E1 Line-Code Violation Counting Options
COUNT EXCESSIVE
E1 CODE VIOLATION SELECT
(ERCNT.0)
ZEROS?
Yes
Yes
No
No
(ERCNT.3)
0
1
-2
before the VCR would saturate
B8ZS ENABLED?
(T1RCR2.5)
Yes
Yes
No
No
COUNTED IN THE LCVCRs
76 of 238
BPVs
BPVs + 16 consecutive 0s
BPVs (B8ZS codewords not counted)
BPVs + 8 consecutive 0s
COUNTED IN THE LCVCRs
BPVs
CVs
(Table
Table 14-A
14-B).
shows what the LCVCRs

Related parts for DS2155L+