SI3018-F-GS Silicon Laboratories Inc, SI3018-F-GS Datasheet - Page 22

IC VOICE DAA GCI/PCM/SPI 16SOIC

SI3018-F-GS

Manufacturer Part Number
SI3018-F-GS
Description
IC VOICE DAA GCI/PCM/SPI 16SOIC
Manufacturer
Silicon Laboratories Inc
Type
Chipsetr
Datasheet

Specifications of SI3018-F-GS

Package / Case
16-SOIC (3.9mm Width)
Function
Data Access Arrangement (DAA)
Interface
Serial
Number Of Circuits
1
Voltage - Supply
3 V ~ 3.6 V
Current - Supply
8.5mA
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Includes
Line Voltage Monitor, Loop Current Monitor, Overload Detection, Parallel Handset Detection, Polarity Reversal Detection, TIP and
Product
Modem Module
Supply Voltage (min)
3 V
Supply Current
15 mA
Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
0 C
Mounting Style
SMD/SMT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Power (watts)
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Si2457/34/15/04
H1
In
I0
I1
I3
I6
I7
I8
Ln
L1
L2
L3
Mn
M0
M1
M2
M3
On
O0
O1
O2
Qn
Q0
Q1
R
Sn
S$
Sn?
Sn=x
Vn
V0
V1
22
Command
Table 10. Basic AT Command Set (Command Defaults in Bold) (Continued)
Go off-hook.
Identification and checksum.
Display Si2457/34/15/04 revision code.
B: Revision B
C: Revision C, etc.
Display Si2457/34/15/04 firmware revision code (numeric).
Display line-side revision code.
18C = Si3018 revision C
Display the ISOmodem® model number.
“2404” = Si2404
“2415” = Si2415
“2434” = Si2434
“2457” = Si2457
Diagnostic results 1. See “AN93: Modem Designer’s Guide” for details.
Diagnostic results 2. See “AN93: Modem Designer’s Guide” for details.
Speaker volume operation
Low speaker volume
Medium speaker volume
High speaker volume
Speaker operation (via AOUT).
Speaker is always off.
Speaker is on while dialing and handshaking; off in data mode.
Speaker is always on.
Speaker is off while dialing, on during handshaking and retraining.
Return to data mode from Command mode operation.
Return to data mode.
Return to data mode and perform a full retrain (at any speed except 300 bps).
Return to data mode and perform rate renegotiation.
Response mode.
Enable result codes (see Table 14 on page 36)
Disable result codes (enable quiet mode).
Initiate V.23 reversal.
S-register operation (see Table 15 on page 39).
List contents of all S registers.
Display contents of S-register n.
Set S-register n to value x (where n and x are decimal values).
Result code type (see Table 14 on page 36).
Numeric result codes.
Verbal result codes
Rev. 1.1
Action