SI3018-F-GS Silicon Laboratories Inc, SI3018-F-GS Datasheet - Page 24

IC VOICE DAA GCI/PCM/SPI 16SOIC

SI3018-F-GS

Manufacturer Part Number
SI3018-F-GS
Description
IC VOICE DAA GCI/PCM/SPI 16SOIC
Manufacturer
Silicon Laboratories Inc
Type
Chipsetr
Datasheet

Specifications of SI3018-F-GS

Package / Case
16-SOIC (3.9mm Width)
Function
Data Access Arrangement (DAA)
Interface
Serial
Number Of Circuits
1
Voltage - Supply
3 V ~ 3.6 V
Current - Supply
8.5mA
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Includes
Line Voltage Monitor, Loop Current Monitor, Overload Detection, Parallel Handset Detection, Polarity Reversal Detection, TIP and
Product
Modem Module
Supply Voltage (min)
3 V
Supply Current
15 mA
Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
0 C
Mounting Style
SMD/SMT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Power (watts)
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Si2457/34/15/04
+DS Options
+DS = A
+DS = A,B
+DS = A,B,C
+DS = A,B,C,D
+ES Options
+ES = A
+ES = A,,C
24
Command
+DR=X
Table 10. Basic AT Command Set (Command Defaults in Bold) (Continued)
Data compression reporting.
X
0
1
If enabled, the intermediate result code is transmitted at the point after error control negotia-
tion. The format of this result code is as follows:
Result code
+DR:NONE
+DR:V42B
+DR:V42B RD
+DR:V42B TD
Controls V.42bis data compression function.
A
B
C
D
Enable synchronous access mode.
A
B
C
Specifies fallback mode of operation.
Disabled
Enabled
Maximum string size
6 to 250 (28 default)
Specifies the mode of operation when initiating a modem connection.
D Disable synchronous access mode.
6 Enable synchronous access mode when connection is completed and data state is
This parameter should not be used.
D Disable synchronous access mode.
8 Enable synchronous access mode when connection is completed and data state is
Mode
Direction
Compression_negotiation
Maximum dictionary size
512
Specifies the mode of operation when answer a modem connection.
0 No compression
1 Transmit only
2 Receive only
3 Both Directions
0 Do not disconnect if V.42 is not negotiated.
1 Disconnect is V.42 is not negotiated.
entered.
entered.
Mode
Data compression is not in use
Rec. V.42bis is in use in both directions
Rec. V.42bis is in use in receive direction only
Rec. V.42bis is in use in transmit directions only
Rev. 1.1
Action