V24A12M400B Vicor Corporation, V24A12M400B Datasheet - Page 2

no-image

V24A12M400B

Manufacturer Part Number
V24A12M400B
Description
Manufacturer
Vicor Corporation
Datasheet
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
ELECTRICAL CHARACTERISTICS
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature,
unless otherwise specified. All temperatures refer to the operating temperature at the center of the baseplate.
Note: For important information relative to applications where the converter modules are subject to continuous dynamic loading,
Parameter
Operating input voltage
Input surge withstand
Output voltage setpoint
Output OVP setpoint
Output power
Efficiency
Parameter
Undervoltage turn-on
Undervoltage turn-off
Overvoltage turn-off/on
Dissipation, standby
Parameter
Line regulation
Load regulation
Temperature regulation
Ripple and noise, p-p
Current limit
Short circuit current
Power sharing accuracy
Programming range
Baseplate
Pin style
MODULE OPERATING SPECIFICATIONS
MODULE OUTPUT SPECIFICATIONS
MODULE MECHANICAL SPECIFICATIONS
MODULE INPUT SPECIFICATIONS
contact Vicor applications engineering at 800-927-9474.
Set your site on VICOR at www.vicorpower.com
Slotted (Style 1)
Short (Style 1)
11.88
14.77
13.7
36.3
23.3
Min
Min
Min
18
85
34
10
±0.002
±0.02
±0.06
14.3
86.8
17.5
15.3
37.8
38.4
38.4
Typ
Typ
Typ
6.8
24
12
70
±2
±0.005
12.12
Max
14.9
Max
17.9
39.6
10.2
Max
±0.2
±0.2
43.5
43.5
400
110
36
50
88
±5
V24A12C400B DC-DC Converter
% / °C
Watts
Watts
Amps
Amps
Unit
Unit
Unit
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
mV
%
%
%
%
%
Notes
<100ms
Nominal input; full load; 25°C
25°C; recycle input voltage to restart ( 1 minute off )
At 100°C baseplate temperature
Nominal input; 75% of full load; 25°C
Notes
No load
Notes
Low line to high line; full load
No load to full load; nominal input
Over operating temperature range
Nominal input, full load; 25°C; 20MHz bandwidth
Output voltage 95% of nominal
Output voltage <250mV
10 to 100% of full load
Of nominal output voltage. For trimming below
90% of nominal, a minimum load of 10% of
maximum rated power may be required.
Slotted baseplate (style 1) requires no designator.
For threaded baseplate add a "2" to the end of the
part number. For thru-hole add a "3".
For long pin configuration add “L” to the end of the
part number. See page 7 for pin dimensions.
Rev. 3
Page 2 of 8

Related parts for V24A12M400B