CONTROL FUNCTIONS - PC PIN
Module Enable/Disable
The module may be disabled by pulling PC below 2.3V with
respect to the –Input. This may be done with an open collector
transistor, relay, or optocoupler. Multiple converters may be
disabled with a single transistor or relay either directly or via
“OR’ing” diodes. See Figure 1.
Primary Auxiliary Supply
At 5.7V, PC can source up to 1.5mA. In the example shown in
Figure 3, PC powers a module enabled LED.
Figure 1—Module enable/disable.
Figure 3—LED on-state indicator.
Figure 5—Isolated on-state indicator.
Enabled"
"Module
Disable = PC <2.3V
Disable
Optocoupler
4k
4k
Set your site on VICOR at www.vicorpower.com
+In
PC
PR
–In
+In
PC
PR
–In
+In
PC
PR
–In
V24A12C400B DC-DC Converter
Module Alarm
The module contains “watchdog” circuitry which monitors
input voltage, operating temperature and internal operating
parameters. In the event that any of these parameters are
outside of their allowable operating range, the module will shut
down and PC will go low. PC will periodically go high and the
module will check to see if the fault (as an example,
overtemperature) has cleared. If the fault has not been cleared,
PC will go low again and the cycle will restart. The SC pin will
go low in the event of a fault and return to its normal state after
the fault has been cleared. See Figures 2 and 4.
Figure 2—PC/SC module alarm logic.
Figure 4—PC/SC module alarm timing.
Figure 6—Secondary side on-state indicator.
Fault
+In
PC
PR
–In
PC
SC
1.23V
5.7V
SW1
"Fault" position
(0-3mA)
5.7Vdc
SW1, 2, & 3
shown in
2-20ms typ.
Restart
f (V IN )
Auto
+Out
–Out
SC
+S
–S
40 s typ.
2-20ms typ.
SW2
Input Undervoltage
Input Overvoltage
Overtemperature
Module Faults
1.00V
50
SW3
1.23
Vdc
Rev. 3
1K
6K
Alarm
+Out
–Out
+S
SC
–S
Page 4 of 8