PS22056 MITSUBISHI, PS22056 Datasheet

no-image

PS22056

Manufacturer Part Number
PS22056
Description
Manufacturer
MITSUBISHI
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PS22056
Manufacturer:
MITSUBISHI
Quantity:
57
Part Number:
PS22056
Manufacturer:
MIT
Quantity:
20 000
Part Number:
PS22056-P
Manufacturer:
MITSUBISHI
Quantity:
57
APPLICATION
AC400V 0.2kW~3.7kW inverter drive for small power motor control.
PS22056
Fig. 1 PACKAGE OUTLINES
INTEGRATED DRIVE, PROTECTION AND SYSTEM CONTROL FUNCTIONS
• For upper-leg IGBT
• For lower-leg IGBT
• Fault signaling : Corresponding to an SC fault (Lower-side IGBT) or a UV fault (Lower-side supply).
• Input interface : 5V line CMOS/TTL compatible (High active logic).
2- 4.5
0.2
All external terminals are treated with lead free solder (ingredient : Sn-Cu) plating.
1 2
8
2.54
S
0.3
S
3 4
(2.5)
22
: Drive circuit, Control supply under-voltage protection (UV), Short circuit protection (SC).
:Drive circuit, High voltage high-speed level shifting, Control supply under-voltage (UV) protection.
0.3
Type name , Lot No.
5 6
23
10.16
30 2.54(=76.2)
MITSUBISHI SEMICONDUCTOR <Dual-In-Line Package Intelligent Power Module>
7 8
24
0.3
67
79
MITSUBISHI SEMICONDUCTOR <Dual-In-Line Package Intelligent Power Module>
0.3
0.5
9 10
Heat sink side
25
QR
Code
11 12 13 14 15 16 17 18 19 20 21
26
27
28
INTEGRATED POWER FUNCTIONS
1200V/25A low-loss 4
for 3 phase DC-to-AC power conversion
Detail : A
(2)
A
Heat sink side
th
generation IGBT inverter bridge
TRANSFER-MOLD TYPE
1. VUFS
2. VUFB
3. VP1
4. UP
5. VVFS
6. VVFB
7. VP1
8. VP
9. VWFS
10. VWFB
11. VP1
12. VPC
13. WP
14. VN1
15. VNC
16. CIN
17. CFO
18. FO
19. UN
20. VN
21. WN
TRANSFER-MOLD TYPE
PS22056
INSULATED TYPE
INSULATED TYPE
22. P
23. U
24. V
25. W
26. NU
27. NV
28. NW
PS22056
Dimensions in mm
May 2005

Related parts for PS22056

PS22056 Summary of contents

Page 1

... All external terminals are treated with lead free solder (ingredient : Sn-Cu) plating. INTEGRATED POWER FUNCTIONS 1200V/25A low-loss 4 for 3 phase DC-to-AC power conversion Heat sink side (2) Detail : A PS22056 PS22056 TRANSFER-MOLD TYPE TRANSFER-MOLD TYPE INSULATED TYPE INSULATED TYPE th generation IGBT inverter bridge Dimensions VUFS 22 VUFB 23 ...

Page 2

... When the sensed shunt voltage exceeds the SC trip-level, all the L-side IGBTs are turned OFF and a fault signal (Fo) is output. Since the SC fault may be repetitive recommended to stop the system and check the fault, when the Fo signal is received. PS22056 TRANSFER-MOLD TYPE INSULATED TYPE C2 ...

Page 3

... Applied between CIN-V NC Condition V = 13.5~16.5V, Inverter part 125 C, non-repetitive, less than 60Hz, Sinusoidal minute, connection pins to heat-sink plate Control terminals Heat-sink T C PS22056 TRANSFER-MOLD TYPE INSULATED TYPE Ratings 900 1000 1200 25 50 78.1 (Note 1) –20~+125 100 C) however, to en- C 125 100 C) ...

Page 4

... C j Trip level Reset level C = 22nF FO Applied between according to the following approximate equation : C FO PS22056 TRANSFER-MOLD TYPE INSULATED TYPE Limits Min. Typ. Max. — — 1.28 — — 1.70 — — 0.047 Limits Min. Typ. Max. — ...

Page 5

... V 800V, CC 13.5 V 16.5V, D 13.5 V 16.5V, DB – 100 line wiring inductance less than 10nH (Note 9) Between V -NU, NV, NW (including surge) NC PS22056 TRANSFER-MOLD TYPE INSULATED TYPE Limits Min. Typ. Max. — 0.98 1.47 — 77 — (Note 6) –50 100 Limits Min. Typ. Max. 350 600 800 13 ...

Page 6

... HVIC3 V V IGBT3 Di3 COM V S IGBT4 LVIC Di4 U OUT IGBT5 Di5 V OUT IGBT6 Di6 OUT CIN GND CFO CFO CIN PS22056 TRANSFER-MOLD TYPE INSULATED TYPE DIP-IPM May 2005 ...

Page 7

... SC reference voltage CR circuit time constant DELAY the circuits start to operate when next input is applied. Dr pulse is not less than the fixed width for very short UV interval. O RESET SET PS22056 TRANSFER-MOLD TYPE INSULATED TYPE RESET b6 b7 May 2005 ...

Page 8

... Using low inductance chip resistor and reducing wiring length to minimize the wiring inductance. NU Shunt resistor NV NW Please insert fast recovery type diode between V and NC NU, NV, NW terminals. PS22056 TRANSFER-MOLD TYPE INSULATED TYPE RESET c5 c6 DIP-IPM , ...

Page 9

... For extra precaution, please refer to Fig.8 • External protection circuit – NV Vref – Vref R + Shunt C resistor – Vref Comparator PS22056 TRANSFER-MOLD TYPE INSULATED TYPE DIP-IPM this wiring is too NW long, short circuit might be caused Shunt C5 resistor N1 terminals. (Example : NC ...

Related keywords