2-440129-2 TE Connectivity, 2-440129-2 Datasheet - Page 3

2-440129-2

Manufacturer Part Number
2-440129-2
Description
Manufacturer
TE Connectivity
Datasheets

Specifications of 2-440129-2

Product Type
Connector
Connector Type
Housing
Number Of Positions
2
Centerline (mm [in])
2.00 [0.079]
Number Of Rows
Single
Locking Interface
Without
Contact Type
Socket
Connector Style
Receptacle
Housing Color
Blue
Ul Flammability Rating
UL 94V-0
Housing Material
Nylon 66
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
2-440129-2
Manufacturer:
TE Connectivity AMP Connectors
Quantity:
11 327
Rev
3.5. TEST REQUIREMENTS AND PROCEDURES SUMMARY
3.5.1
3.5.2.1
3.5.2.2
3.5.2.3
3.5.3.1
3.5.3.2
NO.
D
Conformity of
Product physical
requirements
Termination
Resistance
Insulation
Resistance
Dielectric
Strength
Connector
Mating/
Unmating Force
Individual Pin
Insertion/
Extraction Force
TEST ITEM
Product shall conform to the
requirements of applicable
Product Drawing and Application
Specification
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Insertion Force Extraction Force
Circuit
1000M ohms min. (Initial)
500M ohms min (Finial)
Connector must withstand test
potential of 1000 VAC for 1 min.
Current leakage limit to 5.0mA
max.
Pos
0.7kgf max
Initial
Final
MECHANICAL REQUIREMENT
Initial And 50th Cycle
ELECTRICAL REQUIREMENT
2.5
3.0
3.5
4.0
4.5
5.0
5.5
6.0
6.5
7.0
7.5
8.0
8.5
9.0
9.5
REQUIREMENT
Inserti
max)
(kgf
on
0.8
0.8
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
1.8
2.0
2.0
2.0
10m ohms max.
20m ohms max.
Initial
0.10kgf min
0.08kgf min
Extraction
(kgf min)
(Initial)
(Final)
0.6
0.6
0.8
0.8
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
1.8
1.8
Final
Visually, inspected per applicable
quality inspection plan.
Subject terminated contact and pin to
mate and unmate to measure the force
required to engage and disengage by
operating at a rate of 25mm a minute.
Subject mated contacts assembled in
housing to closed circuit current of
10mA max at open circuit voltage of
20mV max.
Measure by applying test potential
between adjacent contacts, and
between the contacts and ground in
the mated connector assembly.
MIL-STD-202, Method 302,Condition B
Measure by applying test potential
between adjacent contacts, and
between the contacts and ground in
the mated connector assembly.
MIL-STD-202, Method 301
Subject terminated connector and
header to mate and unmate to
measure the force required to engage
and disengage by operating at a rate
of 25mm a minute.
PROCEDURE
108-57100
3 of 6

Related parts for 2-440129-2