2-440129-2 TE Connectivity, 2-440129-2 Datasheet - Page 4

2-440129-2

Manufacturer Part Number
2-440129-2
Description
Manufacturer
TE Connectivity
Datasheets

Specifications of 2-440129-2

Product Type
Connector
Connector Type
Housing
Number Of Positions
2
Centerline (mm [in])
2.00 [0.079]
Number Of Rows
Single
Locking Interface
Without
Contact Type
Socket
Connector Style
Receptacle
Housing Color
Blue
Ul Flammability Rating
UL 94V-0
Housing Material
Nylon 66
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
2-440129-2
Manufacturer:
TE Connectivity AMP Connectors
Quantity:
11 327
Rev
3.5.3.3
3.5.3.4
3.5.3.5
3.5.4.1
3.5.4.2
3.5.4.3
3.5.4.4
3.5.4.5
3.5.4.6
3.5.4.7
3.5.4.8
NO.
D
Tensile Strength
of Wire
Termination
Contact
Retention Force
Post Retention
Force
Vibration
Sinusoidal Low
Frequency
Temperature
Life (Heat Aging)
Humidity, Steady
State
Thermal Shock
Salt Spray
Industrial Gas /
Sulfurous Acid
Gas (SO2)
Solderability
Resistance to
Wave Soldering
Heat
TEST ITEM
AWG #24—3.0kgf min.
AWG #26—2.0kgf min.
AWG #28—1.0kgf min.
AWG #30—0.8kgf min.
1.5 kgf min. per contact
1.0 kgf min. per contact
No electrical discontinuities
greater than 1 microsecond.
Termination resistance (low level)
shall be met.
Termination resistance (low level)
shall be met.
Insulation Resistance (Final)
500 Mohms min.
Termination resistance (low level)
shall be met.Dielectric Strength
shall be met.
Termination resistance (low level)
shall be met.
Must meet electrical requirement.
Termination resistance (low level)
shall be met.
Termination resistance (low level)
shall be met.
The inspected area of each lead
must have 95% solder coverage
minimum.
No physical damage shall occur.
ENVIRONMENTAL REQUIREMEN
REQUIREMENT
Apply an axial pull-off load to terminated
wire of contact. At a rate of 100mm a
minute. The load is applied in the axial
directions
Apply axial load to terminated contact at
a rate of 100mm a minute.
Apply axial pull-off load to post contact
mounted on housing and measure the
force required to dislodge post from
housing.
Subject mated connectors to 10-55-10
Hz traversed in 1 minute at 1.52mm
amplitude
mutually perpendicular planes.
MIL-STD-202, Method 201, Condition A
Subject mated connector assemblies to
temperature
240hours.
Subject mated connectors to steady
state humidity at 40° C and 90- 95% R.H
for 240hrs
MIL-STD-202, Method 103, Condition
B.
Subject mated connector assemblies
on 25 cycle -55 ° C and +85 ° C for 30
minutes each duration at temperature
extremes.
MIL-STD-202, Method 107, Condition A
Subject mated/ unmated connectors to
5% salt concentration for 48 hours.
MIL-STD-202, Method 101, Condition B
Subject mated connector to sulfurous
acid gas (SO2) atmosphere of 3±1 ppm
concentration at 40±2° C for 96 hours
Steam Aging Preconditioning:
1. Intended for nontin and nontin-alloy
leadfinishes for 93+3/-5℃、1hrs.
2. Intended for tin and tin-alloy lead
finishes for 93+3/-5℃、8hrs.
<JESD22-B102D, Condition C>
Solder pot temperature: 245±5℃, 5sec
Solder Temp.:265±5℃, 10±0.5sec.
Tyco spec. 109-202, Condition B
PROCEDURE
life
2 hours in each of 3
at
108-57100
85° C±2° C
4 of 6
for

Related parts for 2-440129-2