AD7796 Analog Devices, AD7796 Datasheet - Page 18

no-image

AD7796

Manufacturer Part Number
AD7796
Description
Low Power 16-Bit Sigma-Delta A/D Converter for Bridge Sensors
Manufacturer
Analog Devices
Datasheet

Specifications of AD7796

Resolution (bits)
16bit
# Chan
1
Sample Rate
n/a
Interface
Ser,SPI
Analog Input Type
Diff-Bip,Diff-Uni
Ain Range
± (Vref/128)
Adc Architecture
Sigma-Delta
Pkg Type
SOP

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD7796BRUZ
Manufacturer:
ADI
Quantity:
1 000
Part Number:
AD7796BRUZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD7796BRUZ-REEL
Manufacturer:
ADI
Quantity:
1 000
AD7796/AD7797
Single Conversion Mode
In single conversion mode, the AD7796/AD7797 are placed in
shutdown mode between conversions. When a single conver-
sion is initiated by setting MD2, MD1, and MD0 in the mode
register to 0, 0, and 1, respectively, the part powers up, performs
a single conversion, and then returns to shutdown mode. The
on-chip oscillator requires 1 ms to power-up. A conversion
requires a time period of 2 × t
indicate the completion of a conversion. When the data-word
has been read from the data register, DOUT/ RDY goes high. If
CS is low, DOUT/ RDY remains high until another conversion is
initiated and completed. The data register can be read several
times, if required, even when DOUT/ RDY has gone high.
DOUT/RDY
DOUT/RDY
SCLK
SCLK
DIN
DIN
CS
CS
ADC
0x08
. DOUT/ RDY goes low to
0x200A
0x58
Figure 15. Continuous Conversion
Figure 14. Single Conversion
Rev. A | Page 18 of 24
DATA
Continuous Conversion Mode
This is the default power-up mode. The AD7796/AD7797
continuously convert, and the RDY pin in the status register
goes low each time a conversion is complete. If CS is low, the
DOUT/ RDY line also goes low when a conversion is complete.
To read a conversion, the user can write to the communication
register, indicating that the next operation is a read of the data
register. The digital conversion is placed on the DOUT/ RDY
pin as soon as SCLK pulses are applied to the ADC. DOUT/ RDY
returns high when the conversion is read. The user can read this
register additional times, if required. However, the user must
ensure that the data register is not being accessed at the completion
of the next conversion, or the new conversion word is lost.
0x58
0x58
DATA
DATA

Related parts for AD7796