CS6422-CSZ Cirrus Logic Inc, CS6422-CSZ Datasheet - Page 23

IC SPEAKERPHONE ENHANCED 20SOIC

CS6422-CSZ

Manufacturer Part Number
CS6422-CSZ
Description
IC SPEAKERPHONE ENHANCED 20SOIC
Manufacturer
Cirrus Logic Inc
Type
Audio Processorr
Datasheet

Specifications of CS6422-CSZ

Package / Case
20-SOIC
Applications
Speakerphones
Mounting Type
Surface Mount
Product
General Purpose Audio Amplifiers
Available Set Gain
34 dB
Thd Plus Noise
0.03 %
Operating Supply Voltage
5 V
Supply Current
10 mA, 50 mA
Maximum Operating Temperature
+ 70 C
Mounting Style
SMD/SMT
Audio - Load Impedance
10 KOhms
Input Offset Voltage
2.12 V
Minimum Operating Temperature
0 C
Supply Voltage (max)
5.5 V
Supply Voltage (min)
4.5 V
Rohs Compliant
Yes
Operating Temperature Range
0°C To +70°C
Digital Ic Case Style
SOIC
No. Of Pins
20
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
598-1200-5

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CS6422-CSZ
Manufacturer:
CIRRUS
Quantity:
61
Part Number:
CS6422-CSZ
Manufacturer:
CIRRUS
Quantity:
4
Part Number:
CS6422-CSZ
Manufacturer:
CIRRUS
Quantity:
20 000
Part Number:
CS6422-CSZR
Manufacturer:
CREE
Quantity:
210
Part Number:
CS6422-CSZR
Manufacturer:
CIRRUS
Quantity:
1 015
3.6.1
3.6.2
3.6.3
3.6.4
3.6.5
3.6.6
DS295F1
PCSEN- PATH CHANGE SENSITIVITY
TDBTS - TX DOUBLE-TALK SUPPRESSION ATTENUATION
RDBTS - RX DOUBLE-TALK SUPPRESSION ATTENUATION
TSTHD - TRANSMIT SUPPRESSION THRESHOLD
TSBIAS - TRANSMIT SUPPRESSION BIAS
TSATT - TRANSMIT SUPPRESSION ATTENUATION
This parameter sets the amount of attenuation inserted into the transmit path when transmit suppres-
sion is engaged.
The Acoustic Interface is likely to have many path changes as people move about in the room where
the full-duplex speakerphone is being used. The sensitivity of the path change detector can be
changed with the PCSen bit. Set PCSen to ‘0’ for high sensitivity and ‘1’ for low sensitivity.
In any adaptive echo cancelling system, there is a trade-off between hearing echo and remaining in
full-duplex when the acoustic path changes. When PCSen is set to ‘0’ for high sensitivity, the CS6422
will tend to drop to half-duplex in the event of a path change, preventing the far-end listener from hear-
ing echo as the adaptive filter adjusts to the new path.
When PCSen is set to ‘1’ for low sensitivity, the CS6422 will tend to remain in full-duplex during the
path change, and the far-end listener may hear some residual echo as the adaptive filter adjusts to
the new path.
This parameter controls the amount of attenuation that is added to the transmit channel during dou-
ble-talk, that is, when parties at both ends of the link are speaking simultaneously.
This parameter controls the amount of attenuation that is added to the receive path during double-talk.
This parameter sets the ERLE requirement for discrimination between echo and near-end speech by
the transmit suppressor. See Section 4.1.4.1, “Transmit Suppression” for full details.
This bias level affects the ease with which near-end speech may break-in or be attenuated by far-end
echo which causes the transmit suppressor to engage. See Section 4.1.4.1, “Transmit Suppression”
for full details.
CS6422