CS3308-CQZ Cirrus Logic Inc, CS3308-CQZ Datasheet - Page 17

IC ANLG VOL CTRL 8CH DGTL 48LQFP

CS3308-CQZ

Manufacturer Part Number
CS3308-CQZ
Description
IC ANLG VOL CTRL 8CH DGTL 48LQFP
Manufacturer
Cirrus Logic Inc
Type
Controllerr
Datasheet

Specifications of CS3308-CQZ

Package / Case
48-LQFP
Applications
High End Audio
Mounting Type
Surface Mount
Product
General Purpose Audio Amplifiers
Output Power
362 mW
Available Set Gain
22 dB
Thd Plus Noise
- 112 dB
Operating Supply Voltage
3.5 V / 5.25 V
Supply Current
36 mA
Maximum Operating Temperature
+ 70 C
Mounting Style
SMD/SMT
Audio Load Resistance
2 KOhms
Input Offset Voltage
0.75 V
Input Signal Type
Single
Minimum Operating Temperature
- 10 C
Output Signal Type
Analog
Supply Voltage (max)
5.25 V
Supply Voltage (min)
3.1 V
Output Type
8-Channel Audio
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
598-1778 - EVALUATION BOARD FOR CS5376598-1496 - BOARD EVAL FOR CS3308 VOL CTRL
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
598-1598

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CS3308-CQZ
Manufacturer:
Cirrus Logic Inc
Quantity:
10 000
Part Number:
CS3308-CQZR
Manufacturer:
Cirrus Logic Inc
Quantity:
10 000
DS702F1
5.4
5.4.1
Volume & Muting Control Architecture
The CS3308’s volume and muting control architecture provides the ability to control each channel on an
individual and master basis.
Individual control allows the volume and mute state of a single channel to be changed independently from
all other channels within the device. The CS3308 provides 8 individual volume and muting controls, each
permanently assigned to one channel within the device.
Master control allows the volume and mute state of multiple channels to be changed simultaneously with a
single register write. The CS3308 provides three master controls, and each may be configured to affect any
group of channels within a device.
Refer to the
on page 21
Control Mapping Matrix
Figure 5
that the individual channel controls are fixed to their respective channel, and the master controls may be
configured to affect any or all channels within the device.
Each master control has a corresponding Master X Mask register which allows the user to select which
channels are affected by the control. By default, each master control is configured to affect all channels
within the device. Referring to
broken by setting or clearing its corresponding bit in the control’s Master X Mask register.
The contents of the Master X Mask registers determine which channels are affected by both a master con-
trol’s volume and mute settings. Refer to the
page 18
for a complete diagram of the CS3308’s volume and muting control architecture.
shows a conceptual drawing of the CS3308’s internal control-to-channel mapping matrix. Notice
for an in-depth description of the operation of the available controls.
“Volume Controls” section beginning on page 19
Volume & Muting
Gain/Attenuation
Channel 1
Channel 2
Channel 3
Channel 4
Channel 5
Channel 6
Channel 7
Channel 8
Controls
Master 1
Master 2
Master 3
Analog
Stages
Figure 5
Figure 5. CS3308 Control Mapping Matrix
Fixed Connection
Ch. 1
below, each configurable connection shown may be made and
Ch. 2
“Volume & Muting Control Implementation” section on
Ch. 3
Control Mapping Matrix
Configurable Connection
Ch. 4
and the
Ch. 5
Ch. 6
“Muting Controls” section beginning
Ch. 7
Ch. 8
CS3308
17

Related parts for CS3308-CQZ