794606-3 TE Connectivity, 794606-3 Datasheet - Page 3

794606-3

Manufacturer Part Number
794606-3
Description
Manufacturer
TE Connectivity
Datasheets

Specifications of 794606-3

Product Type
Contact
Product Line
Micro MATE-N-LOK
Voltage (vac)
250
Current Rating (a)
5
Termination Method
Crimp
Wire Range (mm [awg])
0.20-0.60² [24-20]
Contact Type
Socket
Contact Plating, Mating Area, Material
Gold (30)
Contact Base Material
Phosphor Bronze
Rohs/elv Compliance
Not ELV/RoHS compliant
Lead Free Solder Processes
Not relevant for lead free process
Applies To
Wire/Cable
Packaging Method
Strip
Solderability, dip test.
Crimp tensile.
Vibration, random.
Mechanical shock.
Durability.
Header contact retention.
Crimp contact retention.
Rev D
Test Description
Solderable area shall have a
minimum of 95% solder coverage.
No discontinuities of 1 microsecond
or longer duration.
See Note.
No discontinuities of 1 microsecond
or longer duration.
See Note.
See Note.
Contact shall not dislodge.
See Note.
Contact shall not dislodge.
See Note.
Wire Size
(AWG)
20
22
24
26
28
30
Figure 1 (continued)
MECHANICAL
Requirement
(kg [lb] minimum)
Crimp Tensile
7.95 [17.5]
5.00 [11]
3.60 [7.9]
2.05 [4.5]
1.40 [3.1]
0.77 [1.7]
EIA-364-52,
Category 3 For thru-hole.
EIA-638 for surface mount.
Subject contacts to solderability.
EIA-364-8.
Determine crimp tensile at a
maximum rate of 25 ± 6 mm [.98 ±
.24 in] per minute.
EIA-364-28, Test Condition VII,
Condition D.
Subject mated specimens to 3.10
G's rms between 20-500 Hz. 15
minutes in each of 3 mutually
perpendicular planes.
See Figure 4.
EIA-364-27, Method A.
Subject mated specimens to 50 G's
half-sine shock pulses of 11
milliseconds duration. 3 shocks in
each direction applied along 3
mutually perpendicular planes, 18
total shocks.
See Figure 4.
EIA-364-9.
Mate and unmate specimens for 30
cycles for tin plated specimens, 75
cycles for 15 µin gold plated
specimens, and 150 cycles for 30
µin gold plated specimens at a
maximum rate of 500 cycles per
hour.
EIA-364-29.
Apply an axial load of 1.4 kg [3.1 lb]
to contacts at a rate of 0.45 kg [1 lb]
per second and hold for 6 seconds.
EIA-364-29.
Apply an axial load of 1.81 kg [4 lb]
to contacts at a rate of 0.45 kg [1 lb]
per second and hold for 6 seconds.
Procedure
108-1836
3 of 7

Related parts for 794606-3