ST72324BK6-Auto STMicroelectronics, ST72324BK6-Auto Datasheet - Page 128

no-image

ST72324BK6-Auto

Manufacturer Part Number
ST72324BK6-Auto
Description
8-bit MCU for automotive, 3.8 to 5.5V operating range with 32 Kbyte Flash, 10-bit ADC, 4 timers, SPI, SCI
Manufacturer
STMicroelectronics
Datasheet

Specifications of ST72324BK6-Auto

Hdflash Endurance
100 cycles, data retention 20 years
Clock Sources
crystal/ceramic resonator oscillators, internal RC oscillator and external clock input
4 Power Saving Modes
Slow, Wait, Active Halt, and Halt
On-chip peripherals
128/198
Table 65.
SCI Extended Receive Prescaler Division Register (SCIERPR)
This register is used to set the Extended Prescaler rate division factor for the receive circuit.
Table 66.
SCI Extended Transmit Prescaler Division Register (SCIETPR)
This register is used to set the External Prescaler rate division factor for the transmit circuit.
SCIERPR
5:3 SCT[2:0]
2:0 SCR[2:0]
7:0
Bit
Bit
7
ERPR[7:0]
Name
Name
SCIBRR register description (continued)
SCIERPR register description
SCI Transmitter rate divisor
SCI Receiver rate divisor
6
These 3 bits, in conjunction with the SCP1 and SCP0 bits, define the total division
applied to the bus clock to yield the transmit rate clock in conventional baud rate
generator mode. 
000: TR dividing factor = 1
001: TR dividing factor = 2
010: TR dividing factor = 4
011: TR dividing factor = 8
100: TR dividing factor = 16
101: TR dividing factor = 32
110: TR dividing factor = 64
111: TR dividing factor = 128
These 3 bits, in conjunction with the SCP[1:0] bits, define the total division applied
to the bus clock to yield the receive rate clock in conventional baud rate generator
mode.
000: RR dividing factor = 1
001: RR dividing factor = 2
010: RR dividing factor = 4
011: RR dividing factor = 8
100: RR dividing factor = 16
101: RR dividing factor = 32
110: RR dividing factor = 64
111: RR dividing factor = 128
8-bit Extended Receive Prescaler Register
The extended baud rate generator is activated when a value different from 00h
is stored in this register. Therefore the clock frequency issued from the 16
divider (see
register (in the range 1 to 255).
The extended baud rate generator is not used after a reset.
5
Doc ID13466 Rev 4
Figure
57) is divided by the binary factor set in the SCIERPR
4
ERPR[7:0]
R/W
Function
Function
3
2
Reset value: 0000 0000 (00h)
1
ST72324B-Auto
0

Related parts for ST72324BK6-Auto