The DS1338 serial real-time clock (RTC) is a low-power, full binary-coded decimal (BCD) clock/calendar plus 56 bytes of NV SRAM
Manufacturer
Maxim
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DS133833
Manufacturer:
ON
Quantity:
6 522
Part Number:
DS133833
Manufacturer:
MAXIM
Quantity:
8
Part Number:
DS1338A2-33
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
DS1338C
Manufacturer:
DALLAS
Quantity:
20 000
Part Number:
DS1338C-3#
Manufacturer:
Maxim
Quantity:
1 511
Part Number:
DS1338C-33
Manufacturer:
DALLAS
Quantity:
9
Part Number:
DS1338C-33
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
DS1338C-33#
Manufacturer:
Maxim
Quantity:
133
Part Number:
DS1338C-33#T&R
Manufacturer:
MAXIM
Quantity:
5 000
Part Number:
DS1338C-33+TR
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
DS1338EEVAL
Manufacturer:
DALLAS
Quantity:
20 000
Part Number:
DS1338U-3+T&R
0
I
The DS1338 supports the I
device receiving data is a receiver. The device that controls the message is called a master. The devices that are
controlled by the master are referred to as slaves. The bus must be controlled by a master device, which generates
the serial clock (SCL), controls the bus access, and generates the START and STOP conditions. The DS1338
operates as a slave on the I
and a fast mode (400kHz maximum clock rate) are defined. The DS1338 works in both modes. Connections to the
bus are made through the open-drain I/O lines SDA and SCL.
The following bus protocol has been defined (Figure 5).
Accordingly, the following bus conditions have been defined:
Bus not busy: Both data and clock lines remain HIGH.
Start data transfer: A change in the state of the data line, from HIGH to LOW, while the clock is HIGH, defines a
START condition.
Stop data transfer: A change in the state of the data line, from LOW to HIGH, while the clock line is HIGH, defines
the STOP condition.
Data valid: The state of the data line represents valid data when, after a START condition, the data line is stable
for the duration of the HIGH period of the clock signal. The data on the line must be changed during the LOW
period of the clock signal. There is one clock pulse per bit of data.
Each data transfer is initiated with a START condition and terminated with a STOP condition. The number of data
bytes transferred between START and STOP conditions is not limited and is determined by the master device. The
information is transferred byte-wise and each receiver acknowledges with a ninth bit.
Acknowledge: Each receiving device, when addressed, is obliged to generate an acknowledge after the reception
of each byte. The master device must generate an extra clock pulse that is associated with this acknowledge bit.
A device that acknowledges must pull down the SDA line during the acknowledge clock pulse in such a way that
the SDA line is stable LOW during the HIGH period of the acknowledge-related clock pulse. Of course, setup and
hold times must be taken into account. A master must signal an end of data to the slave by not generating an
acknowledge bit on the last byte that has been clocked out of the slave. In this case, the slave must leave the data
line HIGH to enable the master to generate the STOP condition.
Figure 5. Data Transfer on I
2
C SERIAL DATA BUS
Data transfer can be initiated only when the bus is not busy.
During data transfer, the data line must remain stable whenever the clock line is HIGH. Changes in the data
line while the clock line is HIGH are interpreted as control signals.
2
2
C protocol. A device that sends data onto the bus is defined as a transmitter and a
C bus. Within the bus specifications, a standard mode (100kHz maximum clock rate)
2
C Serial Bus
12 of 16
DS1338 I
2
C RTC with 56-Byte NV RAM