71M6513 Maxim, 71M6513 Datasheet - Page 13

no-image

71M6513

Manufacturer Part Number
71M6513
Description
The 71M6513 and 71M6513H are highly integrated SoCs with an MPU core, RTC, flash, and LCD driver
Manufacturer
Maxim
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
71M6513-IEL
Manufacturer:
TERIDIA
Quantity:
20 000
Company:
Part Number:
71M6513-IELR/F
Quantity:
1 000
Part Number:
71M6513-IGT
Manufacturer:
MITE
Quantity:
8
Part Number:
71M6513-IGT
Manufacturer:
TERIDIA
Quantity:
20 000
Company:
Part Number:
71M6513-IGT
Quantity:
640
Part Number:
71M6513-IGT/F
Manufacturer:
MAXIM
Quantity:
1 300
Part Number:
71M6513-IGT/F
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
71M6513-IGT/F
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
71M6513-IGTR/F
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
71M6513F-IM
Manufacturer:
TERIDIA
Quantity:
20 000
Part Number:
71M6513H-IGT
Manufacturer:
TERIDIAN
Quantity:
1 376
Part Number:
71M6513H-IGT/F
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
71M6513H-IGTR/F
Manufacturer:
Maxim Integrated
Quantity:
10 000
Pulse Generator
The CE contains two pulse generators which create low jitter pulses at a rate set by the CE DRAM registers APULSEW*WRATE
and APULSER*WRATE if EXT_PULSE (a CE input variable in CE DRAM) is 15. This mode puts the MPU in control of pulse
generation by placing values into the APULSEW and APULSER registers (“external pulse generation”).
If EXT_PULSE is 0, APULSEW is replaced with WSUM_X and APULSER is replaced with VARSUM_X. In this mode, the CE
generates pulse based on its internal computation of WSUM_X and VARSUM_X, the signed sums of energy from all three
elements (“internal pulse generation”).
The DIO_PV and DIO_PW bits as described in the Digital I/O section can be programmed to route WPULSE and VARPULSE
to the output pins DIO6 and DIO7 respectively. DIO6 and DIO7 can be configured to generate interrupts, which can be useful
for pulse counting by the MPU (see On-Chip Resources, DIO Ports section).
Real-Time Monitor
The CE contains a Real Time Monitor (RTM), which can be programmed to monitor four selectable CE RAM locations at full
sample rate. The four monitored locations are serially output to the TMUXOUT pin via the digital output multiplexer at the
beginning of each CE code pass (see the Test Ports Section for details)
CE Functional Overview
The ADC processes one sample per channel per multiplexer cycle. Figure 4 shows the timing of the six samples taken during
one multiplexer cycle.
The number of samples processed during one accumulation cycle is controlled by the I/O RAM registers PRE_SAMPS
(0x2001[7:6]) and SUM_CYCLES (0x2001[5:0]). The integration time for each energy output is
For example, PRE_SAMPS = 42 and SUM_CYCLES = 50 will establish 2100 samples per accumulation cycle. PRE_SAMPS = 100
and SUM_CYCLES = 21 will result in the exact same accumulation cycle of 2100 samples or 833ms. After an accumulation
cycle is completed, the XFER_BUSY interrupt signals to the MPU that accumulated data are available.
EQU
0
1
2
3
4
5
Watt & VAR Formula
VA IA
(1 element, 2W 1ø)
VA(IA-IB)/2
(1 element, 3W 1ø)
VA IA + VB IB
(2 element, 3W 3 øDelta)
VA (IA - IB)/2 + VC IC
(2 element, 4W 3ø Delta)
VA(IA-IB)/2 + VB(IC-IB)/2
(2 element, 4W 3ø Wye)
VA IA + VB IB + VC IC
(3 element, 4W 3ø Wye)
PRE_SAMPS * SUM_CYCLES / 2520.6, where 2520.6 is the sample rate [Hz]
A Maxim Integrated Products Brand
Table 3: Standard Meter Equations (inputs shown gray are scanned but not used for calculation)
Inputs used from MUX se-
quence
Mux State:
IA
IA
IA
IA
IA
IA
0
© 2005-2011 Teridian Semiconductor Corporation
VA
VA
VA
VA
VA
VA
1
IB
IB
IB
IB
IB
IB
2
VB
VB
VB
VB
VB
VB
3
IC
IC
IC
IC
IC
IC
4
3-Phase Energy Meter IC
VC
VC
VC
VC
VC
VC
5
Inputs used from alternate MUX
sequence
Mux State:
TEMP
TEMP
TEMP
TEMP
TEMP
TEMP
71M6513/71M6513H
0
DATA SHEET
VA
VA
VA
VA
VA
VA
1
V3
V3
V3
IB
IB
IB
2
VC
VB
VB
V3
V3
V3
3
VC
VC
IC
IC
IC
IC
4
SEPTEMBER 2011
Page: 13 of 104
VC
VC
VC
VC
VC
VC
5

Related parts for 71M6513