71M6513 Maxim, 71M6513 Datasheet - Page 15

no-image

71M6513

Manufacturer Part Number
71M6513
Description
The 71M6513 and 71M6513H are highly integrated SoCs with an MPU core, RTC, flash, and LCD driver
Manufacturer
Maxim
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
71M6513-IEL
Manufacturer:
TERIDIA
Quantity:
20 000
Company:
Part Number:
71M6513-IELR/F
Quantity:
1 000
Part Number:
71M6513-IGT
Manufacturer:
MITE
Quantity:
8
Part Number:
71M6513-IGT
Manufacturer:
TERIDIA
Quantity:
20 000
Company:
Part Number:
71M6513-IGT
Quantity:
640
Part Number:
71M6513-IGT/F
Manufacturer:
MAXIM
Quantity:
1 300
Part Number:
71M6513-IGT/F
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
71M6513-IGT/F
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
71M6513-IGTR/F
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
71M6513F-IM
Manufacturer:
TERIDIA
Quantity:
20 000
Part Number:
71M6513H-IGT
Manufacturer:
TERIDIAN
Quantity:
1 376
Part Number:
71M6513H-IGT/F
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
71M6513H-IGTR/F
Manufacturer:
Maxim Integrated
Quantity:
10 000
71M6513/71M6513H
3-Phase Energy Meter IC
A Maxim Integrated Products Brand
DATA SHEET
SEPTEMBER 2011
t
φ
=
=
delay
o
o
360
t
f
360
delay
T
Where f is the frequency of the input signal and t
is the sampling delay between voltage and current.
delay
In traditional meter ICs, sampling is accomplished by using two A/D converters per phase (one for voltage and the other one
for current) controlled to sample simultaneously. Our Single-Converter Technology, however, exploits the 32-bit signal
processing capability of its CE to implement “constant delay” all-pass filters. These all-pass filters correct for the conversion
time difference between the voltage and the corresponding current samples that are obtained with a single multiplexed A/D
converter.
The “constant delay” all-pass filters provide a broad-band delay β that is precisely matched to the difference in sample time
between the voltage and the current of a given phase. This digital filter does not affect the amplitude of the signal, but
provides a precisely controlled phase response. The delay compensation implemented in the CE aligns the voltage samples
with their corresponding current samples by routing the voltage samples through the all-pass filter, thus delaying the voltage
samples by β, resulting in the residual phase error β – Ф. The residual phase error is negligible, and is typically less than ±1.5
milli-degrees at 100Hz, thus it does not contribute to errors in the energy measurements.