Single Output
Iout (a)
16
Switch Freq (khz)
0 - 1500
Input Range (v)
1.0 - 16
Output Range (v)
0.5 - 12
Pbf
PbF Option Available

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
IR3895MTRPBF
Manufacturer:
IR
Quantity:
8 000
Part Number:
IR3895MTRPBF
Manufacturer:
IR
Quantity:
20 000
Part Number:
IR3895MTRPBF
0
Company:
Part Number:
IR3895MTRPBF
Quantity:
4 800
Company:
Part Number:
IR3895MTRPBF
Quantity:
1 820
I
I
ΔI=Inductor ripple current 
 
 
THERMAL SHUTDOWN 
Temperature sensing is provided inside IR3895. The trip 
threshold is typically set to 145
exceeded, thermal shutdown turns off both MOSFETs and 
resets the internal soft start. 
Automatic restart is initiated when the sensed 
temperature drops within the operating range. There is  
a 20
EXTERNAL SYNCHRONIZATION 
IR3895 incorporates an internal phase lock loop (PLL) 
circuit which enables synchronization of the internal 
oscillator to an external clock. This function is important to 
avoid sub‐harmonic oscillations due to beat frequency for 
embedded systems when multiple point‐of‐load (POL) 
regulators are used. A multi‐function pin, Rt/Sync, is used 
to connect the external clock. If the external clock is 
present before the converter turns on, Rt/Sync pin can be 
connected to the external clock signal solely and no other 
resistor is needed. If the external clock is applied after the 
converter turns on, or the converter switching frequency 
needs to toggle between the external clock frequency and 
the internal free‐running frequency, an external resistor 
from Rt/Sync pin to Gnd is required to set the free‐running 
frequency.  
I
OCP
LIMIT
OCP
= DC current limit hiccup point 
= Current limit Valley Point 
o
C hysteresis in the thermal shutdown threshold. 
I
LIMIT
20
Figure 8: Timing Diagram for  
2
I
FEBRUARY 01, 2012    | DATA SHEET|    Rev 3.0
Current Limit Hiccup  
(2)
 
 
o
C. When trip threshold is 
Single‐Input Voltage, Synchronous Buck Regulator  
 
- 20 -P
 
 
 
 
16A Highly Integrated SupIRBuck  
When an external clock is applied to Rt/Sync pin after the 
converter runs in steady state with its free‐running 
frequency, a transition from the free‐running frequency to 
the external clock frequency will happen. This transition is 
to gradually make the actual switching frequency equal to 
the external clock frequency, no matter which one is 
higher. On the contrary, when the external clock signal is 
removed from Rt/Sync pin, the switching frequency is also 
changed to free‐running gradually. In order to minimize 
the impact from these transitions to output voltage, a 
diode is recommended to add between the external clock 
and Rt/Sync pin. Figure 9 shows the timing diagram of 
these transitions. 
 
 
An internal circuit is used to change the PWM ramp slope 
according to the clock frequency applied on Rt/Sync pin. 
Even though the frequency of the external synchronization 
clock can vary in a wide range, the PLL circuit will make 
sure that the ramp amplitude is kept constant, requiring no 
adjustment of the loop compensation. Vin variation also 
affects the ramp amplitude, which will be discussed 
separately in Feed‐Forward section. 
SW
SYNC
Free Running
Fs1
Frequency
Figure 9: Timing Diagram for Synchronization  
to the external clock (Fs1>Fs2 or Fs1<Fs2)  
Gradually change
Fs2
Synchronize to the
external clock
 
 
...
...
Gradually change
IR3895 
PD‐97746
Return to free-
running freq
Fs1
 