M25P80 Numonyx, B.V., M25P80 Datasheet - Page 41

no-image

M25P80

Manufacturer Part Number
M25P80
Description
8 Mbit, low voltage, serial Flash memory with 75 MHz SPI bus interface
Manufacturer
Numonyx, B.V.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M25P80
Manufacturer:
ST
0
Part Number:
M25P80-AVMN6
Manufacturer:
ST
0
Part Number:
M25P80-AVMN6TP
Manufacturer:
ST
0
Part Number:
M25P80-UMW6TG
Manufacturer:
ST
0
Part Number:
M25P80-UMW6TG
Manufacturer:
ST
Quantity:
20 000
Part Number:
M25P80-VM6G
Quantity:
1 800
Part Number:
M25P80-VMC6G
Manufacturer:
ST
0
Company:
Part Number:
M25P80-VMC6TG
Quantity:
4 000
Company:
Part Number:
M25P80-VMN3TPB
Quantity:
15 000
Part Number:
M25P80-VMN6P
Manufacturer:
MICRON
Quantity:
20 000
Part Number:
M25P80-VMN6P
Quantity:
30
Part Number:
M25P80-VMN6PBA
Manufacturer:
ST
Quantity:
20 000
Part Number:
M25P80-VMN6TP
Manufacturer:
Numonyx
Quantity:
22 500
Part Number:
M25P80-VMN6TP
Manufacturer:
MICRON44
Quantity:
2 163
M25P80
Table 15.
1. Details of how to find the Technology Process in the marking are given in AN1995, see also
2. Typical values given for T
3. t
4. Value guaranteed by characterization, not 100% tested in production.
5. Expressed as a slew-rate.
6. Only applicable as a constraint for a WRSR instruction when SRWD is set at 1.
7. When using the Page Program (PP) instruction to program consecutive bytes, optimized timings are obtained with one
8. int(A) corresponds to the upper integer part of A. E.g. int(12/8) = 2, int(32/8) = 4 int(15.3) =16.
Symbol
t
PP
t
t
sequence including all the bytes versus several sequences of only a few bytes. (1 ≤ n ≤ 256)
SE
BE
CH
(7)
75 MHz available only for products made in T9HX technology, identified with Process digit “4”
+ t
CL
must be greater than or equal to 1/ f
Alt.
AC characteristics (75 MHz operation, Grade 6) (continued)
Page Program cycle time (256 byte)
Page Program cycle time (n bytes, where n = 1 to 4)
Page Program cycle time (n bytes, where n = 5 to
256)
Sector erase cycle time
Bulk erase cycle time
A
= 25°C.
Test conditions specified in
Parameter
C
Table 10
and
Min.
Table 12
int(n/8) × 0.02
Section 12: Part
Typ.
DC and AC parameters
0.64
0.01
0.6
8
(2)
(8)
numbering.
Max.
20
5
3
(1)
Unit
41/52
ms
s
s