B401B System Sensor, B401B Datasheet - Page 2

no-image

B401B

Manufacturer Part Number
B401B
Description
400 Series Plug-in Smoke Detectors
Manufacturer
System Sensor
Datasheet
400 Series Plug-in Smoke Detector Specifications
A05-0205-006
Physical/Operating Specifications
Size
Weight
Operating Temperature Range
Humidity Range
Air Velocity Rating
Construction
Alarm Point, Thermal
Sensitivity
Smoke Detector Spacing
Standby Current
Operating Voltage/Alarm Current
Mounting Base Selection Guide
Base Model Number
B401B
B401BR
B402B
B404B
B406B
B401
B401R
*Functionality contingent on panel compatibility.
**Must be limited by control panel.
Junction Box Selection Guide*
B401/B401R
B401B/BR
B402B/B406B
B404B
*Box depth contingent on base and wire size. Refer to National Electrical Code of local applicable codes for appropriate recommendations.
Single Gang
No
Yes
Yes
No
3.2 in (8.1 cm) H; 4.0 in (10.2 cm) Dia., unflanged base; 6.2 in (15.7 cm) Dia., flanged base
1451: 0.5 lb (227 gm)
5451: 0.3 lb (136 gm)
1451: 32°F to 120°F (0°C to 49°C)
5451: 32°F to 100°F (0°C to 38°C)
10% to 93% RH non-condensing
Ionization: 1200 fpm maximum
Flame retardant Noryl
135°F (57.2°C) or 15°F/min rate-of-rise
1.9% ± 6%/ft Ion
For ion detectors on smooth ceilings (as defined in NFPA 72), spacing of 30 feet (900 sq ft) may be used as a guide. For
thermal detectors on smooth ceilings (as defined in NFPA 72), spacing of 50 feet (2500 sq ft) may be used. Other spacing
may be used depending on ceiling height, high air movements, and other conditions or response requirements.
Ion: 120 µA maximum
Thermal: 100 µA maximum
Mounting base dependent (see Mounting Base Selection Guide below)
Version
UL/ULC
UL/ULC
UL/ULC
UL/ULC
UL/ULC/EN-54
UL/EN-54
EN-54
3.5” Octagon
No
Yes
Yes
No
2-wire*
2-wire*
4-wire
4-wire
2-wire*
2-wire*
2-wire*
Relay Contact Ratings:
Resistive or Inductive (60% power factor) load.
Form A: 2.0 A at 30 VAC/DC
Form C: 0 .6 A at 110 VDC, 2.0 A at 30 VDC
Loop
Type
®
plastic
Yes
4” Octagon
No
Yes
Yes
1.0 A at 125 VAC, 2.0 A at 30 VAC
Current
Limit Resistor
No
Yes
Yes
Yes
No
No
Yes
4” Square
No
Yes
Yes
Yes
Alarm
Contact Type
Form A&C
Form A&C+A
Supervisory
Form C
50 mm
Yes
No
Yes
No
12/24 VDC
24 VDC
24 VDC
120 VAC
24 VDC
12/24 VDC
24 VDC
Nominal
Voltage
††
Flangeless base
A lthough B401B and B401 bases are
capable of operating at 12 and 24
VDC, they cannot be used with the
5451 in 12 V applications.
60 mm
Yes
No
Yes
No
††
††
Current Draw
on Alarm (mA)
10 to 100**
10 to 62
14 to 39
75 mA AC Max.
12 to 100**
10 to 100**
10 to 62
Yes
No
75 mm
No
No