NTS500 Astec Powe, NTS500 Datasheet

no-image

NTS500

Manufacturer Part Number
NTS500
Description
Nts500 Series 500 Watts
Manufacturer
Astec Powe
Datasheet
Total Power:
Input Voltage:
# of Outputs:
NTS500 Series
500 Watts
Special Features
• Active power factor correction
• IEC EN61000-3-2 compliance
• Remote sense
• Power fail and remote inhibit
• Single wire current sharing
• Built-in EMI filter
• Low output ripple
• 5 V standby
• 12 V fan output
• Overvoltage protection
• Overload protection
• Thermal overload protection
• DC power good
• Built in OR-ing diode / FET
• Optional fan cover (-CF suffix)
• PM Bus compliant
• Digital I
• 2 year warranty
• POE isolation on NTS508
Safety
TUV:
cCSAus:
NEMKO:
CB:
CE:
2
C interface
60950
60950
60950
Certificate & report
Mark (LVD)
200 - 500 Watts
85 - 264 Vac
120 - 300 Vdc
Single
Electrical Specifications
Input
Input range:
Frequency:
Inrush current:
Efficiency:
EMI filter:
Safety ground leakage
current:
Output
Maximum power:
Adjustment range:
Standby output:
Fan output:
Hold-up time:
Overload protection:
Overvoltage protection: 20 - 35% above nominal output
85 - 264 Vac (wide range)
47 - 63 Hz
50 A max., cold start @ 25 °C
85% typical at full load, nominal line
FCC Class B conducted and radiated; CISPR22 Class B
conducted and radiated; EN55022 Class B conducted and
radiated; VDE0878PT3 Class B conducted and radiated.
< 0.5 mA @ 50/60 Hz, 264 Vac input
200 W for convection; 500 W with 30 CFM forced air
± 5%
5 V @ 1 A convection, 2 A forced air, regulated, ± 5%
12 V @ 1 A, -5 %, +7%, 0.5 A for -CF version
20 ms @ 500 W load, 115 VAC nominal line at factory voltage setting
Short circuit protection on all outputs. Case overload
protected @ 115 - 130% above peak rating
Embedded Power for
Business-Critical Continuity
Rev. 06.11.09_#87
NTS500 Series
1 of 3

Related parts for NTS500

NTS500 Summary of contents

Page 1

... Adjustment range: ± 5% Standby output convection forced air, regulated, ± 5% Fan output +7%, 0.5 A for -CF version Hold-up time 500 W load, 115 VAC nominal line at factory voltage setting Overload protection: Short circuit protection on all outputs. Case overload protected @ 115 - 130% above peak rating Overvoltage protection 35% above nominal output Embedded Power for Business-Critical Continuity Rev. 06.11.09_#87 NTS500 Series ...

Page 2

... Embedded Power for Business-Critical Continuity Rev. 06.11.09_#87 NTS500 Series Pin Assignments Connector CN1 PIN 1 Line PIN 3 Neutral PIN 5 Ground SK7 PIN 1 V1 swp PIN 2 - Remote Sense 1 5 PIN 3 + Remote Sense PIN 4 5 VSB (standby) ...

Page 3

... Mechanical Drawing CN1 SK7 V out adj. SK8 (CN403) Embedded Power for Business-Critical Continuity Rev. 06.11.09_#87 NTS500 Series Americas 5810 Van Allen Way Carlsbad, CA 92008 USA Telephone: +1 760 930 4600 Facsimile: +1 760 930 0698 Europe (UK) Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355 Asia (HK) ...

Related keywords