NVA3-453TTH Lambda Electronics, NVA3-453TTH Datasheet - Page 3

no-image

NVA3-453TTH

Manufacturer Part Number
NVA3-453TTH
Description
Nv-power 300 Watts, Flexible Power Solution
Manufacturer
Lambda Electronics
Datasheet
ATX Remote on/off
ATX Power Good
Standby Supply
Electrostatic Discharge
Electromagnetic Field
Fast / Burst Transient (ac input)
Fast / Burst Transient (dc output)
Surge Immunity
Conducted RF Immunity
Power Frequency Magnetic Field
Voltage Dips, Variations, Interruptions
Voltage Fluctuations
Radiated Electric Field
Conducted Emissions
Conducted Harmonics
Flicker
Temperature
Derating
Low Temp Startup
Humidity
Shock
Vibration
Altitude
Pollution
NV-300 Datasheet - Document Number 69687 - Revision 4.1 - October 08
GLOBAL SIGNALS
IMMUNITY EN61000-6-2:2005, EN60601-1-2:2001
EMISSIONS EN61000-6-3:2001, EN60601-1-2:2001
ENVIRONMENT
SAFETY APPROVALS
EN 60950-1
UL 60950-1
CSA 22.2 No 60950-1
IEC 60950-1*
CE Mark
* CB certificate and Report available on request
(-N3 and -N4 Option Models)
LV Directive 2006/95/EC (EN60950-1)
0 to 50°C operational, -40°C to 85°C storage (max 12 months).
Full load, with either ‘-F’ option fitted or 1.5m/s air blown from input to output (approximately 10CFM)
50 to 65°C derate each output by 2.5% per °C
-20°C
5 - 95% RH non condensing
±3 x 30g shocks in each plane, total 18 shocks
30g shock = 11ms (+/-0.5msec), half sine
Conforms to EN60068-2-27, EN60068-2-47, IEC68-2-27, IEC68-2-47, JIS C0041-1987.
Conforms to MIL-STD-810E/F, Method 514.4, Pro I, Cat 1,9
Single axis 10 - 500 Hz at 2g (sweep and endurance at resonance) in all 3 planes
Conforms to EN60068-2-6, IEC68-2-6
Conforms to MIL-STD-810E, Method 516.5, Pro I, IV, VI
3,000 metres operational
Degree 2, Material group 3
Date
2006
2007
2003
2005
EN55011, EN55022
EN55011, EN55022
EN61000-3-2
EN61000-3-3
TTL logic level high or open circuit will inhibit all outputs (except Standby)
Logic high indicates ac supply is good and output 1 is within regulation.
Common 0V with power supply. Not affected by ATX remote on/off
-N3 Option = 5V / 2A
-N4 Option = 12V / 1A.
Amendments
EN61000-4-11
EN61000-4-14
NV-POWER SERIES (NV-300)
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
(as per CISPR.11/22) Class B, FCC47 part 15 subpart B
see app note for details
(as per CISPR.11/22) Class B, FCC47 part 15 subpart B
Class A
Compliant - d
EN 61010-1
IEC 61010-1*
IEC 60601-1*
EN 60601-1
UL 60601-1
Check with factory for status of approvals
Class 3
Class 3
Level 3
Level 3
Level 4
Level 4
Level 3
Level 3
Level 4
max
only
Air discharge 8kV
Contact discharge 4kV
Not applicable to open frame units
(12V/m)
(tested to 4.4kV)
(tested to 2.2kV)
Common mode - 2.2kV
Differential - 1.1kV
(12V)
(30A/m)
Criteria B for 5 sec interruption
For 100 - 240V Nominal
2001
2001
1988
1990
2003
Date
with revisions 2006
Amendments
A1, A2, A13
A1, A2
Criteria
A
A
A
A
A
A
A
A
A
3

Related parts for NVA3-453TTH