D4SL-NSK10-LKx Omron, D4SL-NSK10-LKx Datasheet

no-image

D4SL-NSK10-LKx

Manufacturer Part Number
D4SL-NSK10-LKx
Description
Guard Lock Safety-door Switch
Manufacturer
Omron
Datasheet
World's smallest Class 6-contact Guard Lock
Safety-door Switch
<Guard Lock Safety-door Switch D4SL-N>
<Slide Key D4SL-NSK10-LK@>
• Wiring time is reduced with two types of wiring
• A wide variety of built-in switches can be used for
• Key holding force of 1,300 N.
• It is possible to change the key insertion point
• Significantly reduced solenoid current contributes
• Lockout Key to prevent workers from becoming
• The vertical D4SL Guard Lock Safety-door Switch
• The plastic material makes the Slide Key suitable
Guard Lock Safety-door Switch/D4SL-N-mounting Slide Key
D4SL-N / D4SL-NSK10-LK@
methods capable of one-touch attachment and
removal.
various devices.
(4-, 5-, and 6-contact models are available)
without detaching the head.
to the reduction of power supply cost.
trapped inside the hazardous area.
can be easily mounted on 40 × 40 mm aluminum
frames.
for lightweight doors.
Be sure to read the “Safety Precautions”
on page 22.
Guard Lock Safety-door Switch
Terminal
Block Type
www.DataSheet.co.kr
Connector Type
Slide Key
Datasheet pdf - http://www.DataSheet4U.net/
1

Related parts for D4SL-NSK10-LKx

D4SL-NSK10-LKx Summary of contents

Page 1

... Key D4SL-NSK10-LK@> • Lockout Key to prevent workers from becoming trapped inside the hazardous area. • The vertical D4SL Guard Lock Safety-door Switch can be easily mounted on 40 × aluminum frames. • The plastic material makes the Slide Key suitable for lightweight doors. Be sure to read the “ ...

Page 2

... M20, includes M20-to-1/2-14NPT conversion adapter. *2. Connector cables are not included with the connector type and are to be purchased separately. Operation key D4SL-NK@@ (1) Operation Key Type 1: Horizontal mounting 2: Vertical mounting 3: Adjustable mounting (horizontal) 2 D4SL-N @@@@-@ @ @ (1) (2) (3) (4) (4) Door Lock and Release Conduit Size Contact Model 4-contact Model ...

Page 3

... Insert the built-in switch ( into the blank @. 5-contact Model Insert the built-in switch ( into the blank @. 4-contact Model Insert the built-in switch ( into the blank @. D4SL-N / D4SL-NSK10-LK@ Conduit size Model (See Note.) G1/2 D4SL-N2@FA-DN 1/2-14NPT ...

Page 4

... D4SL-N / D4SL-NSK10-LK@ Release Wiring Solenoid voltage/ Key Type method Indicator Connector Terminal block Special (resin) 24VDC (Orange) Connector Terminal block Note: The recommended models for equipment and machinery being exported to Europe are those with an M20 conduit sizes, and for North America, the recommended models are those with a 1/2-14NPT conduit sizes. ...

Page 5

... Horizontal mounting Horizontal mounting (Short) Horizontal mounting (Cushion rubber) Vertical mounting Vertical mounting (Cushion rubber) Adjustable (Horizontal) Connector Cables Cable length D4SL-N / D4SL-NSK10-LK@ Model D4SL-NK1 D4SL-NK1S D4SL-NK1G D4SL-NK2 D4SL-NK2G D4SL-NK3 www.DataSheet.co.kr Model D4SL-CN1 D4SL-CN3 D4SL-CN5 5 Datasheet pdf - http://www.DataSheet4U.net/ ...

Page 6

... The contents are provided as a total set, individual contents cannot be ordered separately. 2. Perform risk assessment for the equipment in question, configure relay units and other safety circuits, and use properly. * The inner lever for D4GL-SK10/D4SL-NSK10 that can not be used for other products and applications. Applicable Door Switches ...

Page 7

... Features The lockout key prevents workers from becoming trapped without using a padlock. Note: Using LEDs of D4SL-N enables confirming whether the door is open or closed and locked or unlocked. Close door Locked (power not supplied to solenoid) The slide handle is closed. Close door Unlocked (power supplied to solenoid) The slide handle is closed ...

Page 8

... Connector/Terminal Notched side is No D4SL-@@@@-D@ Terminal Block Type Two operation key holes The switch has a release key on the back of Can be mounted the switch as well. from four directions. The switch has an indicator on the back of the switch as well. ...

Page 9

... Operating Cycle Examples for Standard Models D4SL-N@@@A-@ (Mechanical Lock Models) Door condition Terminal No. and Contact No. Function 9 E1 Solenoid (NC) Door open/closed detection and lock monitor contacts 4 52 (NC (NC) Door open/closed detection contact 5 31 (NC) ...

Page 10

... D4SL-N / D4SL-NSK10-LK@ Specifications Standards and EC Directives Conforms to the following EC Directives: • Machinery Directive • Low Voltage Directive • EMC Directive • EN1088 • EN60204-1 • GS-ET-19 Certified Standards Certification body TÜV SÜD EN60947-5-1 (certified direct opening) UL UL508, CSA C22.2 No.14 CQC (CCC) GB14048.5 ...

Page 11

... Confirm that sealing properties are sufficient for the operating conditions and environment beforehand. Although the switch box is protected from dust, oil or water penetration, do not use the D4SL in places where cutting chips, oil, water or chemicals may enter through the key hole on the head, otherwise Switch damage or malfunctioning may occur. ...

Page 12

... Connection Example for D4SL-N@SF@-@ E1 9 (+) E2 10 (− safety circuit 4 (Not use control circuit Lock monitor switch To control circuit Connection Example for D4SL-N@NF@-D@ Terminals 12-41 and 22-51 are connected internally (+) E2 10 (−) www.DataSheet.co.kr To safety circuit 2 To safety circuit 4 To control circuit 8 Lock monitor ...

Page 13

... Door open/closed 42-41 detection 22-21 41 32-31 62- Stroke Operation Key Insertion completion position D4SL-N / D4SL-NSK10-LK@ Remarks Only NC contact 11-12 has a certified direct opening mechanism. On The terminals 42-11, 34-33, and 64-63 can be used as unlike poles. Extraction completion position Only NC contact 11-12 has a certified direct opening mechanism. On The terminals 42-11, 34-33, and ...

Page 14

... D4SL-N / D4SL-NSK10-LK@ Contact (door open/ Model closed detection and lock monitor) D4SL-N@E@@-@ 2NC/1NO+ 1NC/1NO D4SL-N@F@@-@ 2NC/1NO+2NC D4SL-N@G@@-@ 3NC+1NC/1NO D4SL-N@H@@-@ 3NC+2NC 2NC/1NO+ D4SL-N@N@@-@ 2NC/1NO D4SL-N@P@@-@ 2NC/1NO+3NC D4SL-N@Q@@-@ 3NC+2NC/1NO D4SL-N@R@@-@ 3NC+3NC 14 Contact Form Door open/ Operating pattern Lock closed monitor detection Lock position ...

Page 15

... B-B Model D4SL-N@@@@-@N Operating characteristics Key insertion force 15 N max. Key extraction force 30 N max. Pre-travel distance 15 mm max. Movement before being locked 3 mm min. D4SL-N@@@@-@ (Terminal Block Type) 26.3 41.7 ±0.2 (62.75) (73.5) Release key (10.85) B-B Model D4SL-N@@@@-@ Operating characteristics Key insertion force 15 N max. ...

Page 16

... D4SL-N / D4SL-NSK10-LK@ Operation key D4SL-NK1 4.3 D4SL-NK1G Two, 4.3 dia. (5.2) Mounting rubber D4SL-NK2G 17 Mounting rubber Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. Connector Cables D4SL-CN@ (30 Connector pin No. Connector Connector No. Lead wire color ...

Page 17

... Two, M6 Switch base mounting holes www.DataSheet.co.kr Close door (26.8) (121) (241.2) SLIDE LOCK 50 (64) SLIDE FREE 90.4 Guide Three Cross-sectional view B-B 4 Cross-sectional view A-A Two, M6 Switch base mounting holes D4SL-N / D4SL-NSK10-LK@ (81.8) (71.8) (30.2) 19 (64) (90.4) Four, M6 mounting holes (19.5) 11.6 (71.8) (39.2) 19.1 (81.8) 8 (115) (78) 12 dia. Inner Lever Four, M6 Slide base mounting holes (19 ...

Page 18

... D4SL-N / D4SL-NSK10-LK@ Operation key Mounting D4SL-N+D4SL-NK1 With Front-inserted Operation Key 59 min. (37) 61.5 max. Key insertion position 59 min. (37) 61.5 max. Key insertion position D4SL-N+D4SL-NK1S With Front-inserted Operation Key 50.5 min. (37) 53 max. Key insertion position 50.5 min. (37) 53 max. Key insertion position D4SL-N+D4SL-NK1G With Front-inserted Operation Key 59 min ...

Page 19

... Center tolerance of Horizontal key hole: ±0.8 insertion radius R > Vertical insertion radius R > 200 = (38.5) 31.5 Center tolerance of key hole: ±0.8 D4SL-N / D4SL-NSK10-LK@ Vertical Center tolerance of insertion radius key hole: ±0.8 Center tolerance of R > 200 (15) = key hole: ±0.8 (17) 9 54.6 min. 54.6 min. 57.1 max. 57.1 max. ...

Page 20

... D4SL-N / D4SL-NSK10-LK@ Application Example G9SA-321-T@ (24VAC/VDC) +D4SL-N@R@A-@ (Mechanical Lock Type) / Manual Reset Lock release signal KM1 KM2 Guard OPEN Stop signal A1 A2 T11 TH SA Timing Chart Limit switch S1 Guard Lock Safety-door Switch S2 Lock release signal ...

Page 21

... G9SA-301 (24 VAC/VDC)+D4SL-N@Q@G-@ (Solenoid Lock Type) / Auto-reset Lock signal OPEN 11 Operation signal A1 A2 T11 T12 T21 Timing Chart Guard opens Limit switch S1 Guard Lock Safety-door Switch S2 Operation signal Lock signal ...

Page 22

... D4SL-N / D4SL-NSK10-LK@ Safety Precautions Be sure to read the precautions for All Safety Door Switches in the website at:http://www.ia.omron.com/. Indicates an imminently hazardous situation which, if not avoided, is likely to DANGER result in serious injury or may result in death. Additionally there may be severe property damage. Indicates a potentially hazardous situation ...

Page 23

... The user must not maintain or repair equipment incorporating the Switch. Contact the manufacturer of the equipment for any maintenance or repairs required. • Refer to the D4SL-N Guard Lock Safety-door Switch Instruction Sheet about storage conditions, ambient conditions, Switch details, and handling methods. ...

Page 24

... Do not use the operation key other than dedicated OMRON's (D4SL-NK@). Otherwise switch may be damaged. • Do not use the operation key D4SL-K@. A lock will not be closed and a machine will not be activated. • Be sure that the operation key can be inserted properly to key hole with a tolerance of ± ...

Page 25

... Do not forcibly insert the wired socket at the cable side into the connector or D4SL-N’s conduit opening. Doing so may cause cable break. Be sure to insert the cable into the connector or D4SL’s conduit opening before performing wiring to the socket, or insert the cable into the connector or conduit opening from the opposite side of the socket ...

Page 26

... Slide Handle Spring washer (M6) • This product is for Omron, the D4SL-NSK10 and the D4GL-SK10 only. This product cannot be used with any other products. • Do not operate the handle with the handle mounting screw removed. Doing so may result in malfunction. ...

Page 27

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON’s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES ...

Page 28

... Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road, PuDong New Area, Shanghai, 200120, China Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200 Authorized Distributor: © OMRON Corporation 2012 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. CSM_1_1_0412 Cat. No. C146-E1-01 0412 (0412) Datasheet pdf - http://www ...

Related keywords