D4SL-N / D4SL-NSK10-LK@
Wiring Precautions for D4SL-N@@@@-@@
Recommended Crimp Terminals
Wiring Precautions for D4SL-N@@@@-@@N
Applicable socket for cable side
L1: 14 mm max.
L2: 8 mm max.
• Do not wire the Switch while power is being supplied. Doing so may
• Do not let particles, such as small pieces of lead wire, enter the
• Do not directly wire the stranded wire to the terminal block.
• When connecting to the terminals via insulating tube and bar
• Applicable lead wire size: AWG22 to AWG18 (0.3 to 0.75 mm
• Use lead wires of an appropriate length. Not doing so may result in
• Remove the terminal block board out of the unit to perform wiring.
• Do not pull on the lead wires with excessive force. Doing so may
• Do not wire the Switch while power is being supplied. Doing so may
• Do not let particles, such as small pieces of lead wire, enter the
• Applicable lead wire size: AWG24 to AWG22 (0.2 to 0.3 mm
• Use lead wires of an appropriate length. Not doing so may result in
• Do not pull on the lead wires with excessive force. Doing so may
• Do not forcibly insert the wired socket at the cable side into the
J.S.T. Mfg Co.
Manufacturer
result in electric shock.
switch body when wiring.
terminals, arrange the bar terminals so that they do not rise up onto
the case or the cover.
excess length causing the cover to rise and not fit properly.
Be sure to insert the connector properly.
disconnect them.
result in electric shock.
switch body when wiring.
Do not apply a current of 2 A or more when using AWG24.
excess length causing the cover to rise and not fit properly.
disconnect them.
connector or D4SL-N’s conduit opening. Doing so may cause
cable break.
Be sure to insert the cable into the connector or D4SL’s conduit
opening before performing wiring to the socket, or insert the cable
into the connector or conduit opening from the opposite side of the
socket.
Manufacturer
CONTACT
PHOENIX
1 2
1
1 3 5
2
3
2
4
7 9
4 6
5
6
10
10
8 10
(applicable wire lead:
L2
AWG24 to AWG22)
L1
AI0.75-8 GY
AI0.34-8 TQ
AI0.5-8 WH
Housing
Contact
Model
Name
1
2
30
3
4
30
±3
5
6
40
±3
mm
mm
±3
7
8 10
mm
9
Applicable wire lead
SXH-001T-P0.6
AWG22
AWG20
AWG18
XHP-10
Model
2
).
2
).
Processing the Conduit Opening
Recommended Connectors
• Connect a recommended connector to the opening of the conduit
• Use the cable with the connector-specified outside diameter.
• For the 1/2-14NPT conduit, mount a provided conversion adapter
• Use a connector with a screw section not exceeding 9 mm.
1/2-
14NPT
• Use LAPP connectors together with Seal Packing (JPK-16 for G1/
• LAPP is a German manufacturer.
• Ace Service Co. is a Japanese manufacturer.
www.DataSheet.co.kr
G1/2
and tighten the connector to the proper torque. The case may be
damaged if excessive tightening torque is applied.
to use the connector above.
Otherwise the screws will protrude into the case interior.
The connectors given in the following table have connectors with
screw sections not exceeding 9 mm.
Use the following connectors to ensure conformance to IP67.
Size
M20
2, or GPM20 for M20), and tighten to the applicable torque. Seal
Packing is sold separately.
Ace Service Co.
Manufacturer
LAPP
LAPP
LAPP
ST-M20×1.5
ST-NPT1/2
5380-1002
5311-1020
5301-6030
ST-PF1/2
Model
LS-2G
Applicable cable
6.0 to 12.0 mm
6.0 to 11.0 mm
7.0 to 13.0 mm
6.0 to 12.0 mm
diameter
Short type
Remarks