IDT82V2048 Integrated Device Technology, Inc., IDT82V2048 Datasheet - Page 38
IDT82V2048
Manufacturer Part Number
IDT82V2048
Description
Manufacturer
Integrated Device Technology, Inc.
Datasheet
1.IDT82V2048.pdf
(61 pages)
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
IDT82V2048BB
Manufacturer:
IDT
Quantity:
17
Company:
Part Number:
IDT82V2048BB
Manufacturer:
IDT
Quantity:
1 831
Company:
Part Number:
IDT82V2048BB
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Company:
Part Number:
IDT82V2048BBG
Manufacturer:
IDT
Quantity:
6
Company:
Part Number:
IDT82V2048BBG
Manufacturer:
IDT
Quantity:
413
Company:
Part Number:
IDT82V2048BBG
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Company:
Part Number:
IDT82V2048DA
Manufacturer:
IDT
Quantity:
12 388
Company:
Part Number:
IDT82V2048DA
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Part Number:
IDT82V2048DA
Manufacturer:
IDT
Quantity:
20 000
Company:
Part Number:
IDT82V2048DAG
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Part Number:
IDT82V2048DAG
Manufacturer:
IDT
Quantity:
20 000
e-LBGE: Inband Loopback Activation/Deactivation Code Generator Enable Register (R/W, Expanded Address = 0F Hex)
Reserved Registers: Primary Registers 16 - 1E and are reservered.
Test Registers: Expand Registers 10 - 1E are test registers. They must be set to 0.
IDT82V2048 OCTAL T1/E1 SHORT HAUL LINE INTERFACE UNIT
e-LBGS: Inband Loopback Activation/Deactivation Code Generator Selection Register (R/W, Expanded Address = 0E Hex)
e-LBI: Inband Loopback Interrupt Status Register (R, Expanded Address = 0D Hex)
LBGE[7:0]
Symbol
Symbol
LBI[7:0]
LBGS[7:0]
Symbol
LBGE.7-0
Position
Position
LBI.7-0
LBGS.7-0
Position
Default
Default
00 H
00 H
Default
00 H
0 = Activation/ Deactivation Code Generator for inband loopback is disabled in transmitter n. (Default)
1 = Activation/Deactivation Code Generator for inband loopback is enabled in transmitter n.
0 = (Default). Or after a read of e-LBS operation.
1 = Any transition on e-LBSn. (Corresponding e-LBMn and bit LBDE in e-LBCF are both set to 1.)
0 = Activation Code Generator is selected in transmitter n. (Default)
1 = Deactivation Code Generator is selected in transmitter n.