AAT2601 Analogic Corporation, AAT2601 Datasheet - Page 31

no-image

AAT2601

Manufacturer Part Number
AAT2601
Description
Manufacturer
Analogic Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AAT2601BIIH-T1
Manufacturer:
KIONIX
Quantity:
34 000
Notes concerning the operation of the CHG
CHG
• Once the part is turned on using the EN_KEY pin (and
• If the part is turned on by connecting supply CHGIN
• The charge current is set by the ISET code in Register
• If the part has been turned on by EN_KEY and CHGIN
2601.2008.01.1.0
2601.2008.01.1.0
If USE_USB = L:
there is a BAT and/or CHGIN supply), and data is sent
through I
be preserved until the part is shut down using the
EN_HOLD (going low) or if the BAT and CHGIN supply
are removed.
(and not through EN_KEY), then when the CHGIN is
removed, the part will shut down and all I
will be cleared.
0x00, bits 2,3,4. (code 000 will equal 100%)
is disconnected then reconnected, it will still contain
the code it had before (if it was 60% then it will
remain 60%).
0
Term
bits or ISET code:
0
0
1
1
1
RCHG
2
C, the I
0
0
1
1
1
Table 5: RCHG Bit Setting for the Battery Charger Recharge Voltage Level.
2
C codes in the registers will always
Table 4: Term Bit Setting for the Termination Current Level.
Term
0
1
0
1
0
RCHG
2
0
1
0
1
2
, CHG
C registers
w w w . a n a l o g i c t e c h . c o m
w w w . a n a l o g i c t e c h . c o m
0
1
Termination Current (as % of Constant Current Charge)
and
Total Power Solution for Portable Applications
Total Power Solution for Portable Applications
• If the part has NOT been turned on by EN_KEY and
If USE_USB = H:
• ISET Code 000 in Register 0x00, bits 2,3,4 = 100mA.
• If the part has been turned on by EN_KEY and CHGIN
• The next time any I
CHGIN is disconnected then reconnected, it will be
reset to 100% (since the whole part was shutdown).
The other codes stay the same as if USE_USB=H.
is disconnected then reconnected, the ISET code will
be forced to 000 and the current will be set to
100mA.
it is not for the ISET code), the ISET code will revert
back to what it was before. For example, if the ISET
code is set to 010 and USE_USB=H and the part was
turned on with EN_KEY, then when CHGIN is discon-
nected then reconnected, the charger will be set to
100mA. Then if any other command is sent, the ISET
code will remain 010.
5% (default)
Recharge Threshold
10%
15%
20%
4.00V (default)
PRODUCT DATASHEET
PRODUCT DATASHEET
2
C register is programmed (even if
4.05V
4.10V
4.15V
AAT2601178
AAT2601178
31
31

Related parts for AAT2601